期刊文献+

应对电网灾变的有限广域智能保护初论 被引量:4

Limited wide area intelligent protection for coping with power network catastrophe
下载PDF
导出
摘要 2008年初我国冰雪灾害造成电网大范围停电和严重破坏,对热点研究的广域保护课题提出新的要求:在以往重点研究大电网稳定破坏事故中保护适用性的基础上,还必须应对极端自然灾害导致网架破坏而引起的特殊问题.有限广域智能保护的基本理念是以提高电网安全"第一道防线"的性能为着眼点,利用有限广域信息与人工智能技术,研究能适应复杂大电网并对各种电网灾变具有自主应对能力的一种新型电网保护系统.介绍有限广域智能保护的关键技术,将有助于从原理性探索向应用研究的转化. In early 2008, large range blackout and severe damage of power networks were caused by the snow and ice disaster in China. New requirements of wide area protection have been put forward : besides the protection adaptability for instability incidents in large power grid, some special problems of network structure destruction caused by extreme disaster must be taken into account. Limited wide area intelligent protection provides the capability of adapting large complex power grid, coping with power network catastrophe and improving performance of power network first defending line by making use of limited wide area information and intelligent technology. Some key technologies for the protection are introduced in this paper, which impels wide area protection form conceptual exploration into applied research.
出处 《电力科学与技术学报》 CAS 2008年第4期13-18,共6页 Journal of Electric Power Science And Technology
基金 国家自然科学基金(50877031)
关键词 继电保护灾害 继电保护 有限广域 智能技术 catastrophe relay protection limited wide area intelligent technology
  • 相关文献

参考文献4

  • 1[7]Bertil Ingelsson,Per-OIof Lindstrom,Daniel Karlsson,et al.Widearea protection against voltage collapse[J].IEEE Computer Applications in Powor,1997,10(2):30-35.
  • 2蔡运清,汪磊,KipMorison,PrabhaKundur,周逢权,郭志忠.广域保护(稳控)技术的现状及展望[J].电网技术,2004,28(8):20-25. 被引量:116
  • 3[9]Serizawa Y,Myoujin M,Kitamura K,et al.Wide-area current dffferontial backup protection employing broadband communications and time transfer systems[J].IEEE Transactions on Delivery,1998,13(4):1046-1052.
  • 4[10]Tan J C,Crossley P A,Mclaren P G,et al.Application of a wide area backup protection expert system to prevent cascading outages[J].IEEE Transactions on Delivery,2002,17(2):350-380.

二级参考文献8

  • 1[1]IEEE Publication NO.90th0358-2-PWR. Voltage stability of powersystems: concepts, analytical tools and industry experience[R]. 1990.
  • 2[2]IEEFE/PES Working Group C-6. Wide area protectionand emergencycontrol[R]. 2002.
  • 3[3]Technical Brochure No. 187, CIGRE. System protection schemes inpower networks[R]. June, 2001.
  • 4[4]Anderson P M, LeReverend B K. Industry experience with specialprotection schemes[J]. IEEE Trans on Power Systems, 1996, 11(3):1166-1179.
  • 5[5]Mid Atlantic Area Council. MAAC special protection system criteria( Document A-3 ) [Z]. 2000.
  • 6[6]Northeast Power Coordinating Council. Special protection systemguideline[Z]. 1988.
  • 7[7]Western Systems Coordinating Council. Guide for remedial actionschemes[Z]. 1991.
  • 8[8]WECC Disturbance Monitoring Work Group. The WECC WAMS in2002[R]. May, 2003.