摘要
目的:探讨一种测量20g以内小鼠心排血量的可行方法,以应用于其他研究。方法:应用RM-6300型八道生理仪及针式电极行阻抗微分法测量,根据相应公式计算每搏心输出量。结果:测得正常小鼠的每分钟心输出量为1.67±0.09ml/分,病毒性心肌炎小鼠模型每分钟心输出量为1.16±0.05ml/分。结论:阻抗微分法是测量20g以内小鼠心排血量的一种可行方法。
Objectives To probe into a feasible method that could survey cardiac output of mouse less than 20g. Methods Impedance differentiation with eightchannel physiogragh,according to the relevant formula to calculate the stroke output. Results The cardiac output of normal mouse is 167±009ml/min,that of viral myocarditis mouse is 116±005ml/min.Conclusions The impedance differentiation is a feasible method to survey cardiac output of mouse less than 20g.
出处
《基础医学与临床》
CSCD
1998年第1期70-71,共2页
Basic and Clinical Medicine