1Bifinci H, Kuruoglu S, Oge I, et al. Effect of intraocular lens and anterior capsule opening type on posterior capsule opacification [ J ]. J Cataract Refract Surg, 1999,25 ( 8 ) : 1140 - 1146.
2Junior SE, Wishart PK. Comparison of PMMA, foldable silicone and foldable acrylic hydrophobic intraocular lenses in combined phacoemulsification and trabeculectomy [ J ]. Arq Bras Oftalmol, 2005,68( 1 ) :29 - 35.
3Wang MC, Woung LC. Digital retroilluminated photography to analyze posterior capsule opacification in eyes with intraocular lenses[J]. J Cataract Refract Surg,2000,26( 1 ) :56 -61.
4Hollick E J, Spalton DJ, Ursell PG, et al. The effect of polymethylmethacrylate, silicone, and polyacrylic intraocular lenses on posterior capsular opacification 3 years after cataract surgery [ J ]. Ophthalmology, 1999,106 ( 1 ) :49 - 54.
5Heatley C J, Spalton D J, Kumar A, et al. Comparison of posterior capsule opacification rates between hydrophilic and hydrophobic single-piece acrylic intraocular lenses [J]. J Cataract Refract Surg ,2005 ,31 (4) :718 -724.
6Georgopoulos M, Menapace R, Findl O, et al. Posterior continuous curvilinear capsulorhexis with hydrogel and silicone intraocular lens implantation:development of capsulorhexis size and capsule opacification[ J ]. J Cataract Refract Surg, 2001,27 ( 6 ) : 825 -832.
7Nishi O, Nishi K, Osakabe Y. Effect of intraocular lenses on preventing posterior capsule opacification:design versus materiall [J]. J Cataract Refract Surg,2004,30(10) :2170 -2176.
9Ram J, Apple D J, Peng Q, et al. Update on fixation of rigid and foldable posterior chamber intraocular lenses, part Ⅱ :choosing the correct haptic fixation and intraocular lens design to help eradicate posterior capsule opacification [ J ]. Ophthalmology, 1999, 106 (5) :891 -900.
10Nishi O, Nishi K, Akura J. Speed of capsular bend formation at the optic edge of acrylic, silicone, and poly ( methyl methacrylate ) lenses[ J]. J Cataract Refract Surg,2002,28 (3) :431 -437.
二级参考文献31
1[1]Schaumberg DA, Dana MR, Christen WG, et al. A systematic overview of the incidence of posterior capsule opacification[J]. Ophthalmology, 1998, 105(7): 1213-1221.
2[2]Sacks HS, Berrier J, Reitman D, et al. Meta-analysis of randomized controlled trials[J]. N Engl J Med, 1987, 316(8):450-455.
3[3]Egger M, Smith GD, Phillips AN. Meta-analysis: principles andprocedures[J]. BMJ, 1997, 315(7121): 1533-1537.
4[4]Egger M, Smith GD, Phillips AN. Meta-analysis: beyond the grand mean[J]? BMJ, 1997, 315(7122): 1610-1614.
5[5]Pogue J, Yusuf S. Overcoming the limitations of current meta-analysis of randomised controlled trials [J]. Lancet,1998, 351(9095): 47-52.
6[6]Olson R J, Crandall AS. Silicone versus polymethylmethacrylate intraocular lenses with regard to capsular opacification[J]. Ophthalmic Surg Lasers, 1998, 29(1): 55-58.
7[7]Hayashi H, Hayashi K, Nakao F, et al. Quantitative comparison of posterior capsule opacification after polymethylmethacrylate, silicone, and soft acrylic intraocular lens implantation[J]. Arch Ophthalmol, 1998, 116(12): 1579-1582.
8[8]Hollick EJ, Spalton DJ, Ursell PG, et al. The effect of polymethylmethacrylate, silicone, and polyacrylic intraocular lenses on posterior capsular opacification 3 years after cataract surgery[J]. Ophthalmology, 1999, 106(1): 49-55.
9[9]Wang MC, Woung LC. Digital retroilluminated photography to analyze posterior capsule opacification in eyes with intraocular lenses[J]. J Cataract Refract Surg, 2000, 26(1): 56-61.
10[10]Hollick EJ, Spalton DJ, Ursell PG, et al. Posterior capsular opacification with hydrogel, polymethylmethacrylate, and silicone intraocular lenses: two-year results of a randomized prospective trial[J]. Am J Ophthalmol, 2000, 129(5): 577-584.
4Hayashi K, Hayashi H. Posterior capsule opacification in the presence of an intraocular lens with a sharp versus rounded optic edge. Ophthalmology. 2005; 112(9): 1550-1556.
7Moisseiev J, Bartov E, Schochat A,et al. Long-term study of the prevalence of capsular opacification following extracapsular cataract extraction. J Cataract Refract Surg. 1989; 15(5):531-533.
8Schauersberger J, Amon M, Kruger A,et al. Lens epithelial cell outgrowth on 3 types of intraocular lenses. J Cataract Refract Surg. 2001 ;27(6):850-854.
9Hollick E J, Spalton D J, Ursell PG, et aI.Biocompatibility of poly(methyl methacrylate), silicone, and AcrySof intraocular lenses: randomized comparison of the cellular reaction on the anterior lens surface. J Cataract Refract Surg. 1998;24(3): 361-366.
10Versura P, Torreggiani A, Cellini M,et al. Adhesion mechanisms of human lens epithelial cells on 4 intraocular lens materials. J Cataract Refract Surg. 1999;25(4):527-533.