期刊文献+

利用SEM-EDS分析火场中白炽灯灯丝通电状态 被引量:3

Analysis of SEM-EDS of incandescent lamp filament debris
下载PDF
导出
摘要 该文模拟火灾现场中白炽灯破坏的不同情况,制备普通白炽灯在不同状态下破坏的灯丝残骸试样,利用扫描电子显微镜-X射线能谱仪分析灯丝残骸表面的微观形貌及其元素组成含量。研究发现,通电状态下被破坏的白炽灯灯丝表面与未通电破坏状态下灯丝表面的元素成分差异较大。经过高温或烟熏的作用,灯丝表面成分也有变化。鉴于不同破坏条件下灯丝表面成分及含量存在明显的差异,可以利用能谱分析的方法判断火场中白炽灯的通电状态。 In this paper, the incandescent lamp filament debris is prepared by different means to simulate the filament debris in fire. The surface composition of filament debris is analyzed by Scanning Electron Microscope and X - ray EDS. It is found that the surface composition of electrified incandescent lamp filament debris is different from the original ones. Under the effect of smoke and high temperature from the imitate fire, the surface composition of electrified filament differs greatly from that of filament not in electrified. Because of the obvious differences in the surface composition of filament, EDS can be used to determine the electric situation of incandescent lamp in fire.
出处 《火灾科学》 CAS CSCD 2009年第1期39-44,共6页 Fire Safety Science
关键词 灯丝 通电状态 X射线能谱分析 火灾 Incandescent lamp filament EDS Electrify station Fire
  • 相关文献

参考文献6

  • 1金河龙.火灾痕迹物证与原因认定[M].长春:吉林科学技术出版社,2005.
  • 2钱钧,马子宁,赵彦军,朱宝礼,朱国.利用扫描电镜研究白炽灯钨丝的热、冷断痕迹[J].广东公安科技,1999,0(4):7-9. 被引量:2
  • 3刘义祥,田宇,胡建国.白炽灯灯丝残骸微观形貌分析[J].火灾科学,2006,15(4):219-223. 被引量:1
  • 4王子夫.关于白炽灯丝断裂问题的浅析[EB/OL].http ://www. 5izm. net/comment, php/4449action=view , 2005- 03- 28.
  • 5PHILIP AISTIN. Fires caused by lighting [J]. Fire Investigation Essay,2000, (5).
  • 6贾常明 等.灯丝的X射线检验[J].中国刑警学院学报,2004,(3):35-38.

二级参考文献5

  • 1胡建国.火灾物证分析[M].北京:警官教育出版社,1999.98-105.
  • 2金河龙.火灾痕迹物证与原因认定[M].长春:吉林科技出版社,2004.384.
  • 3王子夫.关于白炽灯丝断裂问题的浅析[EB/OL].http ://www. 5izm. net/comment, php/4449action=view , 2005- 03- 28.
  • 4贾常明 等.灯丝的X射线检验[J].中国刑警学院学报,2004,(3):35-38.
  • 5李云志,王殿臣.白炽灯破碎前通断电状态的检验研究[J].刑事技术,2002,27(3):23-24. 被引量:2