期刊文献+

术前配戴软性角膜接触镜对激光原位角膜磨削术后泪膜稳定性的影响 被引量:1

Effects of preoperative soft contact lenswear on tear film stability after laser in situ keratomileusis
下载PDF
导出
摘要 目的观察术前配戴软性角膜接触镜与未戴镜患者行激光原位角膜磨削术(LASIK)后泪膜相关指标的差异。方法92例(183眼)近视眼患者在我院行LASIK于术,其中术前配戴角膜接触镜者37例(74眼)为A组,冉根据戴镜时间分为3组,未戴镜者55例(109眼)为B组,分别观察术前,术后1个月、2个月、3个月、6个月、12个月的干眼症状、角膜荧光染色、泪膜破裂时间、泪膜分泌量,两组数据对比并进行统计学分析。结果术前、术后1个月、2个月、3个月、6个月、12个月两组泪膜相关指标均存在差异;戴镜组术后1个月、2个月、3个月、6个月干眼症状、角膜荧光染色、泪膜破裂时间与术前相比均有显著差异。术后12个月恢复至术前水平,术后1个月、2个月、3个月泪液分泌量较术前减少,术后6个月恢复至术前水平;非戴镜组术后1个月、2个月干眼症状、角膜荧光染色、泪膜破裂时间及泪液分泌量与术前相比存在差异,术后3个月恢复至术前水平。戴镜组3组对比,术前术后各组泪膜破裂时间及渭液分泌量亦有差异,并且与戴镜时间呈负相关。结论术前配戴软性角膜接触镜可加重LASIK术后泪膜不稳定,戴镜时间与泪膜相关指标呈负相关,术前术岳应积极预防、治疗,以确保手术疗效。 Objective To observe the difference in tear film stability after LASIK between patients wearing and not wearing soft contact lens preoperatively. Methods 92 myopia patients( 183 eyes)undergoing LASIK were divided into two groups. Group A consisted of 37 patients (74 eyes)wearing soft contact lens preoperatively, and group B included 55 patients ( 109 eyes) not wearing. Group A was divided into three subgroups depending on how long they had worn soft contact lens. Those eyes were all observed for symptoms of eye dryness, epithelial defect, tear break - up time (BUT) and Schirmer's test 1 preoperatively and 1 ,2,3,6, and 12 months postoperatively. Results There were significant differences between the two groups in all the tear film indexes at any time point. In group A, marked decrease in eye dryness, epithelial defect and BUT at 1,2,3,and 6 months postoperatively relative to the preoperative level, and the symptoms returned to the preoperative level at 12 months postoperatively. There were Group A showed marked decreases in Schirmer' s test 1 at 1,2,and 3 months postoperatively relative to the preoperative level, and return to the preoperative level at 6 months postoperatively. In group B, there were obviously decreases in eye dryness, epithelial defect, BUT and Schirmer' s test 1 at 1, and 2 months postoperatively relative to the preoperative level, and return to the preoperative level at 3 months postoperatively. Conclusions Preoperative soft contact lens wearing aggravates the tear film instability after LASIK, and the longer wearing, the worse.
出处 《武警医学》 CAS 2009年第1期20-23,共4页 Medical Journal of the Chinese People's Armed Police Force
关键词 软性角膜接触镜 激光原位角膜磨削术 泪膜 Soft contact lens Laser in situ keratomileusis Tear film
  • 相关文献

参考文献4

二级参考文献27

  • 1侯莹,曾庆广,黄玲.戴角膜接触镜对泪膜稳定性的影响[J].武警医学,2004,15(11):848-849. 被引量:7
  • 2赵少贞,乔丽萍,孙慧敏.软性角膜接触镜诱发角膜改变的共焦显微镜观察[J].眼视光学杂志,2004,6(4):247-249. 被引量:9
  • 3胡艳波,尚宁.爱丽0.1滴眼液治疗干眼症的临床观察[J].航空航天医药,2005,16(2):45-45. 被引量:5
  • 4荣蓓,晏晓明.激光共焦显微镜对正常人眼角膜缘和中央角膜的观察[J].中华眼科杂志,2006,42(1):17-21. 被引量:22
  • 5Conner MS,Stoltz RA,Davis KL. A closed eye contact lens model of corneal inflammation. Part I:increase synthesis of cytochrome R450 arachidonic acid metabolism[J]. Invest Ophthalmol Vis Sci,1995,36(4):838-840.
  • 6Sweency DF. Corneal exhaustion syndrome with lone-time wear contact lenses[J]. Optom Vis Sci,1992,69(4):601-608.
  • 7Linna J,Mullur. Novel aspects of the ultrastructural organization of human corneal keratocytes[J]. Invest Ophthalmol Vis Sci,1995,36(6):2557-2567.
  • 8Cohen SR,Polse KA,Brand RJ. Stromal acidosis affects corneal hydration control[J]. Invest Ophthalmol Vis Sci,1992,33(1):134-135.
  • 9Cohen SR,Polse KA,Brand RJ,et al. The association between pH level and corneal recovery from induced edema[J]. Curr Eye Res,1995,14(4):349-355.
  • 10Mattias Bohnkc,Ahn HE,Badertscher A. Long time contact lens wear induces a corneal degeneration with microdot deposit in the corneal stroma[J]. Ophthalmology,104(11):1889-1896.

共引文献15

同被引文献2

引证文献1

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部