摘要
依据2号机修前考核试验结果以及1号、2号、3号机历史试验数据,对三台机组的热耗、高、中、低压缸效率进行了定性和定量的分析,找出了三台机组热耗较高、高、低压缸效率低、中压缸效率高于设计值的原因。
Based on the data of performance test before overhaul of NO.2 turbine and the historical experimental data of NO.1、NO.2、NO.3 turbines,The reason of higher heat rate of the three turbines as well as lower efficiency of HP、LP has been analyzed qualitatively and quantitatively in this paper.The reasons why heat rate of the three turbines is higher,why efficiency of HP and LP is lower,and why efficiency of IP is higher than design data have been found.
出处
《山东电力技术》
1998年第1期40-43,共4页
Shandong Electric Power