热塑牙胶充填根管的温度损伤的研究 被引量:2

下载PDF
导出
摘要 热塑牙胶充填根管时产生的大量热能会向管壁牙本质及周围组织传导,这种温度的变化是否会对牙体及牙周组织造成热损伤,是决定热塑牙胶根管充填技术临床应用的关键。该文就该技术应用时对牙周造成热损伤的温度阈值的界定、根管表面温度的变化、体内组织学的变化及影响热传导的因素进行了综述。
出处 《口腔医学》 CAS 2009年第1期46-48,共3页 Stomatology
基金 甘肃省科技攻关项目(2GS035-A43-051)
  • 相关文献

参考文献20

  • 1Matthews IS, Hirsch C.Temperature measured in human cortical bone when drilling[J].J Bone Joint SurgAm, 1972, 54 (2) : 297-308.
  • 2Eriksson AR, Albrektsson T. Tempature threshold levels for heat-induced bone tissue injury: a vital-microscop ie study in the rabbit[J]. J Dent, 1983, 50 (1) : 101 - 107.
  • 3Atrizadeh F, Kennedy L,ZanderH. Ankylosis of teeth following themal injury [J]. J Periodontol Res,1971,6(3) :159- 167.
  • 4Lee FS, Van Cura J, Begole E. A comparison of root surface temperature using different obturation heat sources. [J]. J Endod,1998,24 (9) :617-620.
  • 5Lipski M. Root surface temperature rises in vitro during root canal obturation using Hybrid and Microseal techniques[J]. J Endodon,2O05,31(4) :297- 3130.
  • 6Hardie EM. Heat transmission to the outer surface of the tooth during the thermomechanical compaction technique of the root canal obturation[J]. Int Endod J,1986,19(2):73-77.
  • 7Figdor D,Beech DR,Waterson J.Factors affecting heat generation in tire Mc- Spadden compaction technique[J].J Dent Res,1983,13(2):664.
  • 8Lipski M. In vitro intracanal thermographic assessment of root surface temperatures generated by high-temperature thermoplasticized injectable gutta-percha obturation technique[J]. J Am Assoc Endod,2006,32(5):438-441.
  • 9Behnia A,McDonald NJ.In vitro infrared thermographic assessment of root surface temperatures generated by the Thermafil Plus system[J].J Endodon,2001,27(3):203-205.
  • 10宋琳,刘萍,章锦才,邓旭亮.ObturaII热牙胶根管充填系统根管充填时牙根表面温度变化[J].北京口腔医学,2005,13(3):182-183. 被引量:7

二级参考文献14

  • 1Mc Cullagh JJ,Setchell DJ,Gulabivala K,et al.A comparison of thermocouple and infrared thermographic analysis of temperature rise on the root surface during the continuous wave of condensation technique.Int Endod J,2000,33(4):326-332
  • 2Behhia A,McDonald NJ.In vitro infrared thermographic assesssment of root surface temperatures generated by the thermafil plus system.J Endod,2001,27(3):203-205
  • 3Matthews LS,Hirsch C.Temperature measured in human cortical hone when drilling.J Bone Joint Surg Am,1972,54(2):297-308
  • 4Eriksson AR,Albrektsson T.Temperature threshold levels for heatinduced bone tissue injury:a vital-microscopic study in the rabbit.J Prosthet Dent,1983,50(1):101-107
  • 5Rooney J, Midda M, Leeming J. A laboratory investigation of the bactericidal effect of a Nd:YAG laser. Br Dent J,1994,176(1):61~64
  • 6Machida T, Wilder SP, Arrastina AM. Root canal preparation using the second harmonic KTP:YAG laser: a thermographic and scanning electron microscopic study. J Endod,1995,21(2):88~91
  • 7Eriksson AR, Albrektsson T. Temperature threshold level for heat-induced bone tissue injury:a vital-microscopic study in the rabbit. J Prosth Dent,1983,50(1):101~107
  • 8Ramskold L,Fong DC,Stromberg T. Thermal effects and antibacterial properties of energy level required to sterilize stained root canals with an Nd:YAG laser.J Endod, 1997,23(2):96~100
  • 9Lee FS, Van Cura J, Begole E. A comparison of root surface temperature using different obturation heat sources. J Endod,1998,24(9):617~620
  • 10Romero AD, Green DB, Wucherpfenning AL. Heat transfer to the periodontal ligament during root obturation procedures using an in vitro model. J Endod, 2000,26(2):85~87

共引文献18

同被引文献19

引证文献2

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部