期刊文献+

基于DSP的大型发电机槽楔松动检测系统 被引量:4

A detecting system of stator wedges in large generator based on DSP
下载PDF
导出
摘要 大型发电机定子槽楔发生松动会导致定子线棒在电磁力的作用下产生电磁振动,从而加剧定子线棒绝缘的机械磨损及槽内放电引起的绝缘腐蚀,直接威胁着大型发电机的安全运行。通过对大电机的2种不同固定结构槽楔的松动过程进行研究,获取槽楔受迫振动条件下的声音及位移特性来综合判断槽楔的松动程度,并在此振动特性的理论模型及实验基础上,开发了基于DSP数字信号处理的大型发电机槽楔松动检测系统,能够快速准确地检测槽楔的松动性。在电厂现场实测验证了本槽楔松动检测系统的有效性。 Stator bars may get into vibration fiercely caused by the electromagnetic force due to the existence of loose wedges in large generators, which would accelerate the deterioration of the insulation system even make the generators step into calamity ultimately without any treatment. Detection of loose stator wedges is important for reliability of large generators during their operation. It was studied the loose process of stator slot wedge with different fixing style, and makes a judgment of the wedge tight or loose based on its performance of vibrant sound and displacement. Moreover, a loose wedge detecting equipment developed with DSP was mainly introduced.
出处 《中国电力》 CSCD 北大核心 2009年第1期70-74,共5页 Electric Power
基金 国家自然科学基金资助项目(50877037)
关键词 大电机 槽楔松动 DSP 紧固评估 large generator loose wedge DSP tightness assessment
  • 相关文献

参考文献5

二级参考文献29

  • 1栾茹,傅德平,唐龙尧.新型浸润式蒸发冷却电机定子三维温度场的研究[J].中国电机工程学报,2004,24(8):205-209. 被引量:52
  • 2栾茹,傅德平.24kV蒸发冷却汽轮发电机定子绝缘结构的可行性研究[J].中国电机工程学报,2005,25(11):101-106. 被引量:9
  • 3吴欣延.电气绝缘系统无损检测声技术及其应用的研究[M].西安:西安交通大学,1994..
  • 4谢大荣 巫松桢.电工高分子物理[M].西安:西安交通大学出版社,1988..
  • 5项添春.基于虚拟仪器的大电机槽楔松动检测系统 [A]..中国电机工程学会第七届青年学术会议论文集 [C].西安,2002.205-208.
  • 6候国屏,王坤,叶齐鑫,等.LabVIEW7.1编程与虚拟仪器设计[M].北京:清华大学出版社,2005.100—220.
  • 7D.H.Locke, A. Williams.Stator slot wedge testing of large pumped storage generator motors[A].First IEE/IMechE International Conference on Power Station Maintenance-Profitability Through Reliability, 1998:190-195.
  • 8Xie Hengkun, Yue Bo, Hao Yanpeng. Diagnosis of stator winding insulation of large generator[C]. The 7th International Conference on Properties and Applications of Dielectric Materials, Japan, 2003.
  • 9Hao Yanpeng, Wang Guoli, Jia Zhidong, et al. Application of ultrasonic pulse-echo method to insulation condition diagnosis for large generators[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2005, 12(1): 104-113.
  • 10Locke D H, Williams A. Stator slot wedge testing of large pumped storage generator motors[C] . First IEE/IMechE International Conference on Power Station Maintenance-Profitability Through Reliability, Edinburgh, 1998.

共引文献32

同被引文献18

引证文献4

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部