摘要 利用氟离子选择性电极标准曲线法测定电镀铬废水中氟离子含量,得标准曲线方程为y=59.6x?2.2,相关系数接近于1,方法误差为2.0%~5.4%。该法简便、快捷、准确,其测定结果与氟试剂分光光度法的测定结果一致。 A method for the determination of F- in chromium-electroplating wastewater was established based on fluoride ion selective electrode by standard curve. The standard curve regression equation is y = 59.6x - 2.2, and its relativity of the linear regression equation approaches 1.000. The absolute error of the testing ranges from 2.0% to 5.4%. The method is simple, rapid and accurate. The determination result of the method accords with that obtained by spectro- photometry with alizarin complexone as chromogenic reagent.
出处 《电镀与涂饰》 CAS CSCD 北大核心 2009年第2期31-32,共2页 Electroplating & Finishing
基金 江西省高等学校教学研究省级立项课题──基于问题学习法在<仪器分析>中的应用研究(JXJG-O7-7-27)
关键词 电镀铬 废水 氟离子 测定 标准曲线法 离子选择性电极 chromium-electroplating wastewater fluoride ion determination standard curve method ion selective electrode