两种方法诊断OSAHS的比较 被引量:7

Comparison of application between portable sleep monitor and polysomnography in OSAHS
下载PDF
导出
摘要 目的探讨便携式睡眠监测仪在诊断阻塞性睡眠呼吸暂停低通气综合征(OSAHS)中的作用,为临床应用更简易、准确、低成本的诊断方法提供参考。方法采用某进口的多导睡眠仪(PSG)和便携式睡眠监测仪,对60例怀疑有OSAHS的对象均采用两种方法进行监测,比较两种诊断方法各指标的差异,以及便携式睡眠监测仪的敏感性、特异性。结果两种方法所得呼吸紊乱指数、平均血氧饱和度、最低血氧饱和度、低于90%的血氧饱和度时间等均无显著性差异(P>0.05)。与PSG比,便携式睡眠监测仪的敏感性为100%,特异性为60%;对病情分度判断的符合率分别为轻度73.3%、中度71.4%、重度94.4%。结论便携式睡眠监测仪对诊断OSAHS有高敏感性,尤其对重度OSAS的诊断更为准确,适合于临床常规诊断。 Objective To offer an easier, more accurate and lower cost diagnostic method by evaluating the portable sleep monitor in the diagnosis of the obstructive sleep apnea hypoventilation syndrome(OSAHS). Methods 60 cases with suspected OSAHS were monitored with imported portable sleep monitor and the polysomnography simultaneously so as to compare the difference of each parameter provided by the two diagnostic methods as well as to evaluate the sensitivity and specificity of portable sleep monitor. Results There was no significant difference in respiratory disturbance index (RDI), the mean SaO2 ,the minimal SaO2, and percentage of time spent at SaO2 below 90% ( SIT 90% ) between the two diagnostic methods ( P 〉 0. 05 ). Sensitivity and specificity of the portable sleep monitor were 100% and 60% respectively in detecting OSAHS. The corresponse of the specificity of two method was 73.3% ( mild OSAHS) ,71.4% ( moderate OSAHS) and 94. 4% ( severe OSAHS) respectively according to the degree of OSAHS. Conclusions In the diagnosis of OSAHS, the portable sleep monitor is highly sensible and more exact especially for severe OSAHS ,and therefore suitable for routing clinical diagnosis.
出处 《临床肺科杂志》 2009年第3期315-316,共2页 Journal of Clinical Pulmonary Medicine
关键词 便携式睡眠监测仪 多导睡眠监测仪 睡眠呼吸暂停低通气综合征 Portable sleep monitor Polysomnography Obstructive sleep apnea syndrome
  • 相关文献

参考文献5

二级参考文献12

  • 1Young T,Peppard PE,Gottlieb DJ. Epidemiology of obstructive sleep apnea. Am J Respir Crit Care Med, 2002, 165 (9): 1217 ~1239.
  • 2Ip MS,Lam B,Laudeer IJ,et al. A Community study of sleep-disordered breathing in middle~aged Chinese men in Hong Kong .Chest,2001,119(1) :62~69.
  • 3Vazquez JC, Tsai WH, Flemons WW, et al. Automated analysis of digital oximetry in the diagnosis of obstructive sleep apnoea.Thorax 2000;55(4) :302~307.
  • 4Flemons WW. Clinical practice. Obstructive sleep apnea. N Engl J Med,2002,347(7):498~504.
  • 5Herer B,Roche N,Carton M,et al. Value of clinical functional,and oximetric data for the prediction of obstructive sleep apnea in obese. Chest, 1999,116(6): 1537~ 1544.
  • 6Kiely JL, Delahunty C, Matthews S, et al. Comparison of a limited computerize diagnostic system with polysomnography in the diagnosis of obstructive sleep apnoea syndrome[ J ]. Eur RespirJ, 1996,9 (1) : 2 360 -2 364.
  • 7赵忠新.临床睡眠妨碍学[M].上海:第二军医大学出版社,2003:120.
  • 8Flemons WW,Littner MR. Measuring agreement between diagnostic devices[J]. Chest,2003,124(4) :1 535 - 1 542.
  • 9Baltzan MA,Verschelden P, AI Jahdali H ,et al. Accuracy of oximetry with thermistor (OxiFlow) for diagnosis of obstructive sleep apnea and hypopnea[ J]. Sleep,2000,23 ( 1 ) :61 -69.
  • 10Man GC, Kang BV. Validation of a portable sleep apnea monitoring device [ J ]. Chest, 1995,108 ( 2 ) :388 - 393.

共引文献1868

同被引文献105

引证文献7

二级引证文献49

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部