以某加固计算机依据GJB 151/152A测试中RE102辐射发射测试超标的典型案例为研究对象,给出了详细的定位与验证分析过程,并提出了整改措施,整改后的计算机满足RE102要求。
This paper presents research on a representative case of military computer radiation emission that did not meet the re-quirement of RE102, detailed analysis on locating and validating process were given, troubleshooting were carried out to sat-isfy RE102
关键词
军用便携式加固计算机
辐射发射
整改
portable rugged military, computers
radiation emission
troubleshooting