期刊文献+

LASIK手术对人眼波前像差的影响 被引量:1

Effect of LASIK Refractive Surgery on Wave-front Aberration of Human Eye
下载PDF
导出
摘要 采用主观光线追迹的像差仪测量人眼波前像差,比较3mm和6mm瞳孔直径下,LASIK手术前与术后四个月的29只人眼波像差情况.数据比较分析表明,手术后人眼高阶像差一般会大于术前,且像差增大量随术前屈光度数的增大和瞳孔直径的增大而增加,如3mm瞳孔直径下86%的人眼高阶像差的RMSH<0.12μ,>0.4μ.比较人眼波像差的Zernik展开式中各项发现球差Z40无论在3mm还是6mm孔径下术后改变都最大;其中,当比较3阶,4阶和5至7阶时可看出对于3mm孔径第三阶术后改变比例较大,为1.87,6mm时第四阶改变较大,比例为2.21. Employing the subjective ray-tracing aberrometry to measure the wave-front aberration of human eye, the database of 29 eyes previous surgery and post-surgery of four months in the case of pupil diameter with 3ram diameter and 6mm were analyzed,respectively. The results show the high order aberration of post-surgery is usually larger than that of previous surgery,and the increment is growing with the increase of refraction error before surgery and pupil diameter. The high-order aberration RMSH is less than 0.12 μ for 86% of eyes in the case of 3mm pupil diameter,while it is more than 0.4/, for 80% 7 of eyes in the case of 6mm. Comparing every term in the Zernik polynomial of wave-front aberration,it is clear to see that the change of spherical aberration contrasting the third, fourth and ratio of aberration change of the Z4° is the largest no matter for 3ram or 6ram pupil diameter. When fifth-to-seventh order in Zernik polynomial, it is shown clearly that the third order as 1.87 is largest among them for 3mm pupil diameter,while that of the fourth order as 2.21 is the largest for 6mm.
出处 《光子学报》 EI CAS CSCD 北大核心 2009年第1期148-151,共4页 Acta Photonica Sinica
基金 国家自然科学基金重点项目(60438030) 教育部南开大学天津大学合作基金项目 天津市科技攻关项目(033183711)资助
关键词 主观像差仪 高阶像差 LASIK手术 Subjective aberrometry High order wave-front aberration LASIK refractive surgery
  • 相关文献

参考文献3

二级参考文献23

  • 1[1]Martinez CE,Applegate RA,Klyce SD,et al. Effect of pupillary dilation on corneal optical aberrations after photorefractive keratectomy[J]. Arch Ophthalmol,1998,116:1053-1062.
  • 2[2]Oliver KM,Hemenger RP,Corbett MC,et al. Corneal optical aberrations induced by photorefractive keratectomy[J]. J Refract Surg,1997,13:246-254.
  • 3[3]Oshika T,Klyce SD,Applegate RA,et al. Comparison of corneal wavefront aberrations after photorefractive keratectomy and laser in situ keratomileusis[J]. Am J Ophthalmol,1999,127:1-7.
  • 4[4]Seiler T,Kaemmerer M,Mierdel P,et al. Ocular optical aberrations after photorefractive keratectomy for myopia and myopic astigmatism[J]. Arch Ophthalmol,2000,118:17-21.
  • 5[5]Mierdel P,Krinke H-E,Wiegand W,et al. Messplatz zur Bestimmung der monochromatische. Aberration des Menschlichen Auges[J]. Ophthalmologe,1997,94:441-445.
  • 6[6]Mierdel P,Kaemmerer M,Mrochen M,et al. An automated aberrometer for clinical use[J]. SPIE Proc,2000,3908:86-92.
  • 7[7]Verdon W,Bullimore M,Maloney RK. Visual Performance after photorefractive keratectomy; a prospective study[J]. Arch Ophthalmol,1996,114.1465-1472.
  • 8[8]Mrochen MC,Kaemmerer M,Riedel R,Seiler T. Why do we have to conside the corneal curvature for the calculation of customized ablation profiles? ARVO abstract 3669[J]. Invest Ophthalmol Vis Sci,2000,41(4):S689.
  • 9[9]Seiler T,Genth U,Holschbach A,Derse M. Aspheric photorefractive keratectomy with excimer laser[J]. Refract Corneal Surg,1993,9:166-172.
  • 10[10]He Jc,Burns SA,Marcos S. Monochromatic aberrations in the accommodated human eye[J]. Vis Res,2000,40:41-48.

共引文献78

同被引文献15

  • 1毕宏生.对比敏感度在眼科的临床应用[J].中华眼科杂志,2004,40(9):645-648. 被引量:58
  • 2王玲,金成鹏.视网膜视力计及其临床应用[J].临床眼科杂志,2004,12(6):564-567. 被引量:3
  • 3安连生.应用光学[M].3版.北京:北京理工大学出版社,1997:104-111.
  • 4HOOD D C,FINKELSTEIN M A.Sensitivity to light[M]//BOFF K R,KAUFMAN L,THOMAS J P.Handbook of perception and human performance,volume 1:sensory processes and perception[M].New York:John Wiley & Sons,1986:874-875.
  • 5GOODMAN J W.Introduction to fourier optics[M].New York:McGraw-Hill Inc,1968.
  • 6MING Liu,WANG Zhao-Qi,WANG YAN,et al.The study of wavelength-dependent wavefront aberrations based on individual eye model[J].Optik,2008,119:383-387.
  • 7HUBEL D H.Eye,brain,and vision[M].Scientific American Library,1988:162-164.
  • 8CAMPBELL F W,GREEN D G.Optical and retinal factors affecting visual resolution[J].J Physiol,1965,181:576-593.
  • 9CAMPBELL F W,ROBSON J G.Application of fourier analysis to the visibility of gratings[J].J Physiol,1968,197:551-566.
  • 10FELIPE A,ARTIGAS J M,PONS A M.Human contrast sensitivity in coherent Maxwellian view:effect of coherent noise and comparison with speckle[J].JOSA,1997,14(5):972-983.

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部