期刊文献+

双源CT冠状动脉成像中影响图像质量的因素分析 被引量:14

Analysis on the influence factors of imaging quality during DSCT coronary angiography
下载PDF
导出
摘要 目的分析双源CT(doube source computed tomography,DSCT)冠状动脉成像中影响图像质量的因素。方法回顾性分析150例临床可疑或确诊冠心病经手术治疗后复查的患者,男性103例,女性47例,平均年龄60.6岁;均经DSCT冠状动脉成像,对其图像质量影响因素进行了回顾性分析。结果扫描技术直接影响冠状动脉成像的质量。影响图像的因素分为呼吸伪影,心律不齐伪影,上腔静脉、右房高密度造影剂产生的伪影,冠状动脉支架产生的伪影,上述各种伪影均具有独特的影像特征。结论优化CT扫描技术,准确分析冠状动脉成像伪影的CT表现及成因,对保证冠脉成像质量,减少诊断失误有着至关重要的作用。 Objective To analyze the influencing factors of imaging quality during double-source computed tomography(DSCT) coronary angiography.Methods A hundred and fifty patients (103 men and 47 women,mean age, 60.6 years)with clinically suspected or definitely diagnosed coronary heart disease underwent DSCT coronary angiography.The influencing factors of imaging quality in all patients were retrospectively analyzed.Results The study demonstrated that,the scanning techniques could directly affect the imaging quality of coronary arteries,while these influencing factors were mainly the artifacts induced by varied causes such as respiratory movements,arrhythmia,hyperdense contrast medium remained in superior vena cava or right atrium,and coronary stent etc.Different artifacts had certain imaging feature.Conclusion Optimzing the scanning technique and carefully analyzing the appearance and cause of the artifacts are very important to ensure imaging quality and to reduce leaky-misdiagnosis of coronary heart disease.
出处 《实用医学影像杂志》 2009年第1期9-11,共3页 Journal of Practical Medical Imaging
关键词 双源CT 冠状动脉成像 图像质量 影响因素 Double-source CT Coronary angiography Imaging quality Influence factor
  • 相关文献

参考文献6

二级参考文献17

  • 1姜荣,吴晓华,贺文.心率波动对多层螺旋CT冠脉造影图像质量的影响[J].中国医学影像技术,2004,20(10):1574-1576. 被引量:49
  • 2杨明放,王荣品,何强.16层CT冠状动脉成像技术及临床应用[J].实用放射学杂志,2005,21(9):915-918. 被引量:21
  • 3Nieman K,Oudkerk M,rensing BJ,et al.Coronary angiography with multi-slice computed tomograpgy[J].Lancet,2001,357(9256):599-603.
  • 4Abbara S,Cury RC,Nieman K,et al.Noninvasive evaluation of cardiac veins with 16-MDCT angiography[J].Am J Roentgenol,2005,185(4):1001-1006.
  • 5Hong C,becker CR,Huber A,et al.ECG-gated reconstructed multi-detector row CT coronary angiography:effect of varying trigger delay on image quality[J].Radiology,2001,220(3):712-717.
  • 6Manghat NE,Morgan-Hughes GJ,Marshall AJ,et al.Multi-detector row computed tomography:imaging the coronary arteries[J].Clin Radiol,2005,60(9):939-952.
  • 7Schoenhagen P,Halliburton SS,Stillman AE,et al.Noninvasive imaging of coronary arteries:current and future role of mutli-detector row CT[J].Radiology,2004,232(1):7-17.
  • 8Schoepf UJ,Becker CR,Ohnesorge BM,et al.CT of coronary artery disease[J].Radiology,2004,232(1):18-37.
  • 9Austen WG,Edwards JE,Frye RL et al.A reporting system on patients evaluated for coronary artery disease.Report of the Ad Hoc Committee for Grading of Coronary Artery Disease,Council on Cardiovascular Surgery,American Heart Association[J].Circulation,1975,51(4 Suppl):5-40.
  • 10Nieman K,Cademartiri F,Lemos PA,et al.Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography[J].Circulation,2002,106(16):2051-2054.

共引文献130

同被引文献98

引证文献14

二级引证文献38