期刊文献+

后囊膜划开人工晶状体光学部夹持治疗后发性白内障 被引量:4

Posterior capsulorhexis capsulorhexis combined capsular fixation of posterior intraocular lens in after-cataract
下载PDF
导出
摘要 目的:评价后囊膜划开联合人工晶状体光学部后囊膜夹持术治疗后发性白内障的临床疗效。方法:对30例(34眼)因后发性白内障在行后囊膜划开联合人工晶状体光学部后囊膜夹持术患者进行回顾性分析,记录术前及术后的最佳矫正视力、屈光度数和眼压。观察手术并发症、术后眼部情况,随访时间为6~24mo。结果:术中34眼人工晶状体光学部后囊膜夹持成功,手术成功率达100%;术后最佳矫正视力〉0.5,占59%(20/34),术后患者随访期间均未出现视轴混浊,人工晶状体位置正,无其他严重并发症发生,仅出现短期的炎症反应。结论:后囊膜划开联合人工品状体光学部后囊膜夹持术是治疗后发性白内障安全、有效的办法,但手术要求有较高的显微操作技巧。 AIM: To assess the clinical effects of posterior capsulorhexis combined capsular fixation of posterior intraocular lens in after-cataract. METHODS, Thirty cases (34 eyes) received posterior capsulorhexis combined capsular fixation of posterior intraocular lens in after-cataract. Preoperative and postoperative best corrected well visual acuity, refraction and lOP were recorded. Intraoperative and postoperative complications were observed. The follow-up period was from 6 to 24 months. RESULTS, Posterior capsulorhexis combined capsular fixation of posterior intraocular lens was successfully performed in 30 eyes (100%). The postoperative best corrected well visual acuity achieved 0.5 or better in 20 eves (59%). No eves with optic capture were found optic axis opaque. The location of posterior intraocular lens was exact. No serious complications were found, there was only temporary inflammatory reaction. CONCLUSION. Posterior capsulorhexis combined capsular fixation of posterior intraocular lens is safe and effective in treating after-cataract, but it requests higher micro-operation skills.
出处 《国际眼科杂志》 CAS 2009年第2期363-364,共2页 International Eye Science
关键词 后发性白内障 后囊膜划开术 最佳矫正视力 after-cataract posterior capsulorhexis best corrected well visual acuity
  • 相关文献

参考文献10

二级参考文献32

  • 1周昱,唐罗生.Nd:YAG激光治疗后发障的临床研究[J].国际眼科杂志,2004,4(4):699-701. 被引量:17
  • 2丁正华,严宏,王建伟.后发性白内障的发病机制和药物防治的研究现状及前景[J].国际眼科杂志,2006,6(2):412-416. 被引量:28
  • 3Tburschwell LM. Presurgical evaluation of patients with cataracts[J].Optom Clin, 1991,1 (2): 159 - 187.
  • 4Bradley A, Thibos L, Still D. Visual acuity measured with clinical maxwellian-view systens: effects of beam entry location[J]. Optom Vis Sci, 1990,67(11) :811 - 817.
  • 5Lachenmayr B. Predicting visual acuity in media opacities and uncorrectable refractive errors. Assessing so-called "retinal visual acuity"[J]. Fortschr Ophthalmol, 1990,87(Suppl) :S11g - 137.
  • 6Minkowski JS, Palese M, Guyton DL. Potential acuity meter using a minute aerial pinhole aperture [J]. Ophthalmology, 1983, 90:1360-1368.
  • 7Bemharrd Lachenmayr. Potential vision sharpness with impaired refraction medium[M]. Munich, 1993.54 - 94.
  • 8Tharp A, Cantor L, Yung CW, et al. Prospective comparison of the Heine retinometer with the Mentor Guyton-Minkowski potential acuity metex for the assessrment of potential visual acuity before cataract surgery[J]. Ophthalmic Surg, 1994,25(9):576 - 579.
  • 9Faulkner W. Predicting acuities in capsulotomy patients:interferometers and potential acuity rneter[J]. J Am Intraocul Implant Soc, 1983,9(4) :434 - 437.
  • 10Tashiro T, Masuda H, Ichioka T. Clinical study for prediction of postoperative visual acuity in cataract patients[J]. Meikai Daigaku Shigaku Zasshi, 1990,19(1): 117 - 121.

共引文献112

同被引文献17

引证文献4

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部