期刊文献+

双塔式电压发生器地震反应计算 被引量:1

Seismic response computation for twin-tower voltage generator
下载PDF
导出
摘要 以直流电压发生器结构的抗震计算为例,讨论了采用不同模型对双塔结构地震反应计算结果的影响.数值分析的结果表明:当采用单体模型计算时,主结构的计算结果与整体模型的计算结果差异不大,而从结构采用单体模型计算时,地震反应的数值较整体模型计算结果大,说明当主从双塔结构作为整体抵抗地震作用时,主结构会分担一部分作用在从结构上的地震荷载.通过输入不同场地类型地震波的双塔结构地震反应计算,讨论了双塔式直流电压发生器结构采用单体结构计算模型时应取的修正系数. Pertaining to the anti-seismic analysis for a direct current voltage generator, the seismic response analysis is adopted for a twin-tower structure based on various models. It is observed that, while applying the single-body computation, the computational results between the primary tower and entire structural model are quite similar, thus seismic response values of the secondary tower are larger than those of the structural model. This is because the primary sidering various on-site seismic structure shares the seismic loading acting on the secondary structure. By conwaves, different correction coefficients are postulated for single-body computational models of twin-tower direct current voltage generator structures.
出处 《中国工程机械学报》 2008年第4期388-393,共6页 Chinese Journal of Construction Machinery
关键词 直流发生器 时程分析 主结构 从结构 direct current voltage generator time domain analysis primary structure secondary structure
  • 相关文献

参考文献5

二级参考文献6

  • 1Naeim F, Anderson J C. 1993. Classification and Evaluation of Earthquake Records for Design[R]. The Nehrp Professional Fellowship Report to EERI and FEMA, 84-106.
  • 2中华人民共和国建设部.GB 50011-2001 建筑抗震设计规范[S].北京:中国标准出版社,2001..
  • 3R.W.克拉夫,J.彭津.结构动力学[M].北京:科学出版社,1981.
  • 4中华人民共和国电力工业部.GB 50260-96 电力设施抗震设计规范[S].北京:中国计划出版社,1996.
  • 5楼梦麟 陈群丽.考虑滑移和提离效应的电压发生器的地震反应[J].地震工程与工程振动,1999,19(1):164-171.
  • 6翟长海,谢礼立.估计和比较地震动潜在破坏势的综合评述[J].地震工程与工程振动,2002,22(5):1-7. 被引量:27

共引文献124

同被引文献10

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史