摘要 对实验室制作的平均粒径为4mm的宏观各向同性粒状多晶冰,在冰温分别为-0.5、-2、-5和-10℃及应变率分别为4.2×10-4、5.5×10-5、5.5×10-6及3.5×10-7s-1下进行了单轴抗压强度实验。结果表明,极限抗压强度与负温和应变率的对数均呈正比例关系;在较高应变率下(4.2×10-4s-1),在-5℃时,出现韧脆性转折点。 Samples for the polycrystalline ice, which is macroscopically isotropic and with an average grain size of 4mm, are made in laboratory. The uniaxial compressive strength tests are conducted at temperatures of -0.5,-2,-5 an -10℃ respectively and at strain rates of 4.2×10 -4 , 5.5×10 -5 , 5.5×10 -6 and 3.5×10 -7 s -1 respectively. Test results show that the ultimate compressive strength of the polycrystalline ice is directly proportional to the temperature and also to the logarithm of strain rate. It is found that ductile brittle transition for the polycrystalline ice occurs at temperature -5℃ when the strain rate is 4.2×10 -4 s -1 .
出处 《实验力学》 CSCD 北大核心 1998年第1期92-97,共6页 Journal of Experimental Mechanics
关键词 多晶冰 抗压强度 实验 人造冰 冰工程 力学性质 polycrystalline ice compressive strength