论述了消火栓给水系统设计时中美两国消防设计规范的不同之处和美标中可借鉴之处,结合消火栓系统、消防主泵、消防稳压泵的设计和选型,讨论了如何将中美消防规范有机地结合进行涉外工程设计。
Author has discussed the differences of fire fighting codes between Chinese and American two countries in design of hydrant feed water system and has described the points we can use for reference. In combination with design/selection for the hydrant system, main pump for fire fighting and pressure stabilization pump for fire fighting, author has also discussed how to make the foreign project design in a close combination of the Chinese fire fighting code with the American fire fighting code.
出处
《化肥设计》
CAS
2009年第1期27-29,共3页
Chemical Fertilizer Design
关键词
中国
美国
消防设计规范
消火栓给水系统
消防主泵
消防稳压泵
差异
China
USA
fire fighting design code
hydrant feed water system
main pump of fire fighting
pressure stabilization pump for fire fighting
China