摘要
对江西省奥体中心游泳、跳水馆工程进行简介,对空调冷热源设计、空调通风及采暖系统设计中的一些做法进行介绍和分析。该项目设计中,采用了地源热泵、排风热回收、地板辐射采暖等节能措施;在空调通风气流组织上结合场馆特点进行了合理的规划;采取了一系列综合措施来实现建筑围护结构的防结露。
The project of Swimming and Diving Gymnasium of Jiangxi Provincial Olympics Sports Center was briefly introduced. Some techniques in heating and cooling source design and HVAC system design was analyzed. In this project, some measures were adopted for energy saving, including soil source heat pump, exhaust air heat recovery, floor panel heating and etc. Air distribution was designed properly according to the features of architecture. A series of measures were also applied to prevent the building envelope from dewing.
出处
《建筑热能通风空调》
2009年第1期100-103,共4页
Building Energy & Environment
关键词
空调冷热源
地源热泵
气流组织型式
地板辐射采暖
heating and cooling source, soil source heat pump, air distribution mode, floor panel heating