根据线性装药在钢筋混凝土墙拆除爆破中的实验结果,得出了最佳药量,最佳间距和最小抵抗线等参数,并将实验结果应用于实际工程,得到了满意效果。
This paper gives an analysis of best dosage, best hole distance, minimum burdenand other parameters according to experimental results of linear ram on demolition of reinforced concrete wall, applies experimental results to practical projects, and has given asatisfying result.
出处
《爆破》
CSCD
1998年第2期33-36,共4页
Blasting
关键词
线性装药
拆除爆破
钢筋混凝土墙
linear charge
wall demolition
controlled blasting