期刊文献+

数值模型对输电铁塔内力和变形的影响分析 被引量:20

The Influence Analysis of Numerical Model on Internal Force and Structural Deformation of Power Transmission Tower
下载PDF
导出
摘要 以某典型输电铁塔为背景,采用数值分析方法,进行了梁桁混合模型与剐聚模型的建楔,井对计异结果进行对比分析,得出两种模型对于输电塔杆件内力和变形的影响规律。研究表明,刚架模型的最大综合位移与梁桁模型相差2%以内,这说明主材和斜材对于塔架整体刚度贡献较大,辅助材对整体剐度贡献较少。同一工况下梁桁混合模型与刚架模型的轴力、应力结果相应之比集中在1.002~1.020区间内,可见粱桁混合模型受力结果稍微大于刚架模型,混合模型结构设计偏于安全。该研究分析为输电铁塔设计模型的计算与选择提供了依据。 A typical power transmission tower was numerically analyzed. The rigid frame model and mixed model with beam and truss were established. And the influence of two models on the internal force and deformation is obtained from the computing results. The results indicate that the difference of maximal displacement between mixed model and rigid frame model is within 2%. In other words, the stiffness effect of main bars and diagonal bars is greater than that of secondary bars. The research also indicates that the ratio of the internal forces between mixed model and rigid frame model is greater than 1, ranging from 1. 002 to 1. 020. Therefore, in the same load case, the internal forces of mixed model are larger than that of rigid frame model. Hence, it provides the basis for the calculation and selection of design model of the power transmission tower.
出处 《山东科技大学学报(自然科学版)》 CAS 2009年第1期40-45,共6页 Journal of Shandong University of Science and Technology(Natural Science)
基金 国家自然科学基金项目(50478100)
关键词 输电铁塔 内力 变形 梁桁混合模型 刚架模型 power transmission tower internal force deformation mixed model with beam and truss rigid frame model
  • 相关文献

参考文献8

  • 1杨元春,张克宝.输电跨越塔设计回顾与展望[J].特种结构,2006,23(3):70-76. 被引量:9
  • 2赵滇生.输电塔架结构的理论分析与受力性能研究[D].杭州:浙江大学,2003.
  • 3Ida SILVA J G S, da S VELLASCO P C G, de ANDRADE S A L, et al. Structural assessment of current steel design models for transmission and telecommunication towers[J]. Journal of Constructional Steel Research, 2005,61 (8):1108-1134.
  • 4ALBERMANI F G A, KITIPORNCHAI S. Numerical simulation of structural behavior of transmission towers[J]. Thin- Walled Structures,2003,41(2) :167-177.
  • 5PRASADRAO N, KALYANARAMAN V. Non-linear behavior of lattice panel of angle towers[J]. Journal of Constructional Steel Research,2001,57(12) :1337-1357.
  • 6赵滇生,金三爱.有限元模型对输电塔架结构动力特性分析的影响[J].特种结构,2004,21(3):8-11. 被引量:64
  • 7何远宾.输电线钢塔的有限元分析与研究[D].西安:西安建筑科技大学,2002.
  • 8杨万里,鲍务均,龙小乐.输电杆塔结构的非线性有限元设计分析[J].湖北电力,1999,23(1):25-27. 被引量:6

二级参考文献17

  • 1J.A.T.De.Freitas and A.C.B.S.Ribeiro.Large Displacement Elasto-plastic Analysis of Space Trusses.Computer & Structure,1992,Vol.44,No.5,pp1007-1016
  • 2Yan Hui、Liu Yanjun,Zhao Diansheng.Geometric Nonlinear Analysis of Transmission Tower with Continous Legs.Advances in Steel Structures,Pergamon,1996,Vol.1,No.5,pp339-344.
  • 3.110-500kV架空送电线路设计技术规程[M].北京:中国电力出版社,1999..
  • 4.高耸结构设计规范(GBJ135-90)[M].北京:中国建筑工业出版社,1990..
  • 5GB50017-2003.钢结构设计规范.[S].中华人民共和国建设部,..
  • 6Lattice tower and masts partl:Code of practice for loading BS 8100: PART1 : 1986
  • 7架空送电规程 JEAC 6001-2000.
  • 8Eurocode 3: Design of steel structures prEN 1993-1-1:2003
  • 9Euroeode 3: Design of steel structures ENV 1993-1-1 April 1992
  • 10[美]J.W.费雪,J.H.A.斯特鲁克.螺栓和铆钉连接设计准则指南.人民交通出版社,1983.

共引文献76

同被引文献143

引证文献20

二级引证文献80

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部