Application of empirical mode decomposition based energy ratio to vortex flowmeter state diagnosis 被引量:4

Application of empirical mode decomposition based energy ratio to vortex flowmeter state diagnosis
下载PDF
导出
摘要 To improve the measurement performance, a method for diagnosing the state of vortex flowmeter under various flow conditions was presented. The raw sensor signal of the vortex flowmeter was adaptively decomposed into intrinsic mode functions using the empirical mode decomposition approach. Based on the empirical mode decomposition results, the energy of each intrinsic mode function was extracted, and the vortex energy ratio was proposed to analyze how the perturbation in the flow affected the measurement performance of the vortex flowmeter. The relationship between the vortex energy ratio of the signal and the flow condition was established. The results show that the vortex energy ratio is sensitive to the flow condition and ideal for the characterization of the vortex flowmeter signal. Moreover, the vortex energy ratio under normal flow condition is greater than 80%, which can be adopted as an indicator to diagnose the state of a vortex flowmeter. To improve the measurement performance, a method for diagnosing the state of vortex flowmeter under various flow conditions was presented. The raw sensor signal of the vortex flowmeter was adaptively decomposed into intrinsic mode functions using the empirical mode decomposition approach. Based on the empirical mode decomposition results, the energy of each intrinsic mode function was extracted, and the vortex energy ratio was proposed to analyze how the perturbation in the flow affected the measurement performance of the vortex flowmeter. The relationship between the vortex energy ratio of the signal and the flow condition was established. The results show that the vortex energy ratio is sensitive to the flow condition and ideal for the characterization of the vortex flowmeter signal. Moreover, the vortex energy ratio under normal flow condition is greater than 80%, which can be adopted as an indicator to diagnose the state of a vortex flowmeter.
出处 《Journal of Central South University》 SCIE EI CAS 2009年第1期154-159,共6页 中南大学学报(英文版)
基金 Project(200801346) supported by the China Postdoctoral Science Foundation Project(2008RS4022) supported by the Hunan Postdoctoral Scientific Program Project(2008) supported by the Postdoctoral Science Foundation of Central South University
关键词 流量计 测试方法 水流条件 传感器 flow state diagnosis energy ratio vortex flowmeter empirical mode decomposition
  • 相关文献

参考文献11

  • 1孙志强,周孑民,周萍.Application of Hilbert-Huang transform to denoising in vortex flowmeter[J].Journal of Central South University of Technology,2006,13(5):501-505. 被引量:4
  • 2WAKUI H,,WADA M,YOSHIOKA T,ANDOH T."DigitalYEWFLO multivariable type" vortex flowmeter with built-in temperature sensor[].Yokogawa Technical Report.2004
  • 3ROSSBERG A G,BARTHOLOME K,TIMMER J.Data-driven optimal filtering for phase and frequency of noisy oscillations: application to vortex flow metering[].Physical Review.2004
  • 4IGARASHI T.Resistance and Strouhal number of a vortex shedder in a circular pipe[].JSME International Journal.1999
  • 5SUN Zhi-qiang,ZHANG Hong-jian,ZHOU Jie-min.Evaluation of uncertainty in a vortex flowmeter measurement[].Measurement.2008
  • 6Tavoularis S.Measurement in Fluid Mechanics[]..2005
  • 7Pankanin,G L.The vortex flowmeter: various methods of investigating phenomena[].Measurement Science and Technology.2005
  • 8Amadi-Echendu J E,Zhu H J.Signal analysis applied to vortex flowmeters[].IEEE Transactions on Instrumentation and Measurement.1992
  • 9GHAOUD T,CLARKE D W.Modeling and tracking avortex flow-meter signal[].Flow Measurement and In-strumentation.2002
  • 10Bera S C,Ray J K,Chattopadhyay S.A modified inductive pick-up type technique of measurement in a vortex flowmeter[].Measurement.2004

二级参考文献10

  • 1Bogue,R W.The confusing world of flow sensing[].Sensor Review.2005
  • 2Yoder J.Flowmeters and their apps: an overview[].Sensors.2003
  • 3Pankanin,G L.The vortex flowmeter: various methods of investigating phenomena[].Measurement Science and Technology.2005
  • 4SUN Hong-jun,ZHANG Tao,WANG Hua-xiang.Wavelet denoising method used in the vortex flowmeter[C]∥[].Proceedings of nd International Conference on Machine Learning and Cybernetics.2003
  • 5SUN Hong-jun,ZHANG Tao.Digital signal processing based on wavelet and statistics method for vortex flowmeters[C]∥[].Proceedings of rd International Conference on Machine Learning and Cybernetics.2004
  • 6PENG Jie-gang,FU Xin,CHEN Ying.Flow measurement of by a new type vortex flowmeter of dual triangulate bluff body [ J][].Sensors and Actuators.2004
  • 7Jan Y,Sheu T W.A numerical confirmation of the dual body vortex flowmeter design [ J][].Computers and Fluids.2004
  • 8Bera S C,Ray J K,Chattopadhyay S.A modified inductive pick-up type technique of measurement in a vortex flowmeter[].Measurement.2004
  • 9Clarke D W.Designing phase-locked loops for instrumentation applications [ J][].Measurement.2002
  • 10Ghaoud T,Clarke D W.Modelling and tracking a vortex flow-meter signal[].Flow Measurement and Instrumentation.2002

共引文献3

同被引文献57

引证文献4

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部