从调节池容积和结构形式的确定以及防腐设计方面总结了垃圾卫生填埋场渗沥液调节池设计中应注意的问题及采取的措施。
Some advertent problems and measures in design of leachate regulating tank in waste sanitary landfill sites were summarized from determination of volume, structural style, and anticorrosion design of the tank.
出处
《环境卫生工程》
2009年第1期63-64,共2页
Environmental Sanitation Engineering
关键词
垃圾填埋场
调节池
容积
结构形式
防腐蚀设计
抗渗
waste landfill site
regulating tank
volume
structural style
anticorrosion design
impervious