期刊文献+

石墨水泥砂浆注浆钢纤维混凝土板融雪试验 被引量:4

Experimental Study on Graphite Slurry Infiltrated Fiber Concrete Slab for Snow Melting
下载PDF
导出
摘要 采用渗浇工艺制作了石墨水泥砂浆注浆钢纤维混凝土(GSIFCON)板.对该板的电热性能和冬季野外融雪性能进行了试验研究.结果表明:GSIFCON板通电产生的热量可有效融化积雪.在GSIFCON板的底面和侧面分别设置3 cm厚聚乙烯泡沫保温层时,其融雪热效率可达20%以上,较无保温层的GSIFCON板其融雪效率提高约5%.应用这种技术,可有效避免除冰盐对混凝土和环境带来的负面影响. Graphite slurry infiltrated fiber concrete(GSIFCON) slabs were manufactured successfully by infiltration technology. The electrothermal properties and snow melting tests in field of the slabs were carried out. The experimental ruslts indicate that the thermal energy produced by GSIFCON slab makes snow melt effectively. The electrothermal efficiency for melting snow of the slab with 3 cm thin polyethylene insulating layer can reach above 20%, nearly 5% more than that of the slab without the insulating layer. The application of this technology can avoid the negative effects on concrete and environment caused by using deicing salt.
作者 洪雷 张健
出处 《建筑材料学报》 EI CAS CSCD 北大核心 2009年第1期96-100,共5页 Journal of Building Materials
基金 建设部研究开发项目(2008-K4-31)
关键词 石墨 钢纤维 电热效率 融雪 graphite steel fiber electrothermal efficiency snow melting
  • 相关文献

参考文献4

二级参考文献25

  • 1李长太,钱觉时,唐祖全.钢渣机敏混凝土的性能研究[J].混凝土与水泥制品,2005(2):5-8. 被引量:7
  • 2洪雷.石墨砂浆渗浇钢纤维混凝土导电机理研究(英文)[J].山东建筑大学学报,2006,21(4):295-300. 被引量:10
  • 3洪雷,孙维才,孙宏伟.石墨砂浆渗浇钢纤维混凝土的导电性能及机敏性能研究[J].混凝土,2006(11):16-19. 被引量:11
  • 4洪雷,宋玉普.石墨水泥砂浆注浆钢纤维混凝土导电性能研究[J].建筑材料学报,2006,9(6):649-653. 被引量:14
  • 5[1]Lankard S R,Newell J K.Preparation of highly reinforced steel fiber reinforced concrete composites[A].Hoff G C.Fiber reinforced concrete,International Symposium[C].New York:SP-81,ACI.1984.289-306.
  • 6[2]Naaman A E,Homrich J R.Tensile stress-strain properties of SIFCON[J].ACI Materials Journal,1989,86 (3):244-251.
  • 7[3]Parameswaran V S,Krishnamoorthy T S,Balasubramanian K.Behavior of high volume fiber cement mortar in flexure[J].Cement and Concrete Composite,1990,12(4):293-301.
  • 8[4]Farhad R,Gordo B B,Yamamuro J A,et al.Volume electrical resistivity of carbon fiber cement composites[J].ACI Materials Journal,1998,98 (1):25-34.
  • 9[5]Xu L F,Chung D D L.Carbon fiber reinforced mortar as an electrical contact material for cathodic protection[J].Cement and Concrete Research,1995,125(4):689-694.
  • 10[6]Hong L.The properties of concrete and the technology of new type concrete[M].Dalian:Dalian University of Technology Press,2005.191-198(in Chinese).