摘要
目的:评价BioPure MTAD作为根管冲洗液对根管充填糊剂AH Plus根尖封闭性能的影响。方法:选取人单根管牙44颗,随机分为A、B、C、D、E、F等6组,分别选用蒸馏水、1.3%NaClO、5.25%NaClO+17%EDTA、1.3%NaClO+BioPure MTAD和1.3%NaClO+3%EDTA等几组冲洗液进行根管冲洗。预备后进行根管充填,将所有实验样本染色,采用透明牙技术测量根尖微渗漏长度。采用SPSS12.0软件包对结果进行方差分析。结果:C组(1.3%NaClO)、D组(5.25%NaClO+17%EDTA)、E组(1.3%NaClO+BioPure MTAD)、F组(1.3%NaClO+3%EDTA)根尖微渗漏长度分别为(1.81±0.73)mm、(0.53±0.49)mm、(0.40±0.44)mm和(0.39±0.55)mm,C组微渗漏长度显著大于其他3个实验组(P<0.05);而D、E、F组根尖微渗漏情况无统计学差异(P>0.05)。结论:与临床常用根管冲洗液组合相比,BioPure MTAD冲洗根管对根管充填糊剂AHPlus的根尖封闭性能无明显不良影响。
PURPOSE: To evaluate whether BioPure MTAD could affect the apical sealing ability of AH Plus sealer in vitro.METHODS: Forty-four extracted single-rooted human teeth were randomly divided into six groups. The canals were treated with distilled water, 1.3%NaClO,5.25 %NaClO±17%EDTA,1.3%NaClO±BioPure MTAD and 1.3%NaClO±3%EDTA endodontie irrigants, respectively. After obturated, the teeth were made transparent and permitted dye penetration,then measured by using a stereoscopic microscope. SPSS 12.0 software package was used for One-way ANOVA. RESULTS: The microleakages lengths of obturated root canals in group C,D,E,F were (1.81±0.73)mm, (0.53±0.49)mm, (0.40±0.44)mm and (0.39±0.55)mm, respectively.Group C had significantly more leakage than group D,E,F (P〈0.05), but there were no significant differences among group D,E,F (P〉0.05). CONCLUSION: Compared with other endodontic irrigants which usually used in clinic, BioPure MTAD doesn' t adversely affect the apical sealing ability of AH plus sealer.
出处
《上海口腔医学》
CAS
CSCD
2009年第1期86-89,共4页
Shanghai Journal of Stomatology