期刊文献+

冠状动脉CT血管造影检查中心率及心率波动 被引量:8

Analysis of Heart Rate and Heart Rate Variation During Cardiac CTA
下载PDF
导出
摘要 目的:探讨冠状动脉CT血管造影(CTA)检查过程中心率的变化及波动。方法:208例患者纳入研究,心率高于70bpm的75例患者口服β受体阻滞剂至心率小于70bpm。比较平静呼吸时(基础心率)、扫描前深吸气时及扫描期间屏气时3个时期的心率及心率波动。结果:扫描期间的平均心率明显低于基础心率[(59.8±9.0)bpm;(63.9±7.8)bpm;P<0.01],以平均心率±5bpm以外的心率为波动心率,其所占百分比在平静呼吸时与屏气时无统计学差异(P>0.05),但均与深吸气时有明显差异(P<0.05)。患者是否服用β受体阻滞剂对扫描期间心率波动没有明显影响(P>0.05)。结论:冠脉CTA扫描过程中心率会有所下降,但心率波动不增加。 Purpose: To discuss the change of heart rate and heart rate variability during cardiac CT angiography (CTA) . Methods: Two hundred and eight patients underwent coronary CTA. Seventy five patients with heart rate greater than 70 bpm were pretreated with oral β blockers. Mean heart rate and percentage of beats outside a±5 bpm around the mean were compared between baseline (free breathing), prescan hyperventilation, and scan acquisition (breath - hold). Results: Mean scan acquisition time was 14.0 ±2.8 seconds for coronary CTA. Mean heart rate during scan acquisition was significantly lower than that at baseline (59.8± 9.0bpm, 63.9 ± 7.8 bpm, P 〈 0.01 ). The percentage of beats outside a ± 5 bpm around the mean were not different between baseline and CTA scanning(3.6%, 3.4%, P = 0.78) . The buccal of β blockers had no significant effect on heart rate or percentage of beats outside a ± 5 bpm around the mean(P 〉 0.05) .Conclusion: Breath- holding during cardiac CT scan acquisition significantly lowers the mean heart rate, but heart rate variability is the same or less when compared with normal breathing.
出处 《中国医学计算机成像杂志》 CSCD 北大核心 2009年第1期35-37,共3页 Chinese Computed Medical Imaging
关键词 心率 体层摄影术 X线计算机 冠状动脉造影术 Heart rate Tomography,X - ray computed Coronary angiography
  • 相关文献

参考文献7

  • 1Lu B, Zhuang N, Mao SS, et al. Baseline heart rate - adjusted electrocardiographic triggering for coronary artery electronbeam CT angiography. Radiology, 2004, 233:590-595.
  • 2Boll DT, Gilkeson RC, Merkle EM, et al. Functional cardiac CT and MR: effects of heart rate and software applications on measurement validity. J Thorac Imaging, 2005, 20: 10- 16.
  • 3Brodoefel H, Reimann A, Burgstahler C, et al. Noninvasive coronary angiography using 64 - slice spiral computed tomography in an unselected patient collective: effect of heart rate, heart rate variability and coronary calcifications on image quality and diagnostic accuracy. Eur Radiol, 2008, 66: 134- 141.
  • 4Hoffmann MH, Shi H, Manzke R, et al. Noninvasive coronary angiography with 16 - detector row CT : effect of heart rate. Radiology, 2005, 234: 86-97.
  • 5Achenbach S , Ropers D , Kuettner A , et al . Cont rastenhanced coronary artery visualization by dual - 2 - source computed to- mographyinitial experience. Eur J Radiol, 2006, 57:331 - 335.
  • 6Johnson TR , Nikolaou K, Wintersperger BJ , et al . Dual - 2- source CT cardiac imaging : initial experience . Eur Radiol, 2006, 16 : 1409- 1415.
  • 7Brodoefel H, Burgstahler C, Tsiflikas I, et al. Dual - source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy. Radiology, 2008, 247: 346 - 355.

同被引文献66

引证文献8

二级引证文献46

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部