期刊文献+

中空纤维帘式与平板式膜组件在浸没式MBR中的对比试用研究 被引量:8

COMPARATIVE PILOT TESTS ON A SUBMERGED MEMBRANE BIOREACTOR(MBR) SYSTEM OF HOLLOW-FIBER AND FLAT-SHEET MEMBRANE MODULE
下载PDF
导出
摘要 选取两种不同结构类型的膜组件进行化工废水处理的中试应用研究,对比研究了MBR膜系统的最佳气水比、临界膜通量、膜系统的分离与处理效果以及膜的污染和清洗方式。中试结果表明,在该类废水处理中,中空纤维帘式膜组件的最佳气水比为24,平板式膜组件的最佳气水比为20;在同等曝气强度下,用流量阶梯法测得,中空纤维帘式膜组件的临界膜通量为20L·m-2·h-1,平板式膜组件的临界膜通量为25L·m-2·h-1;两组膜在处理和分离效果上相差不大;在抗污染性能上,平板式膜组件更具优势,而且平板式膜组件更容易通过物理清洗-空曝气的方式使膜通量得以部分恢复,用次氯酸钠(NaClO)溶液对膜组件进行化学清洗,均能获得较好的通量恢复效果。 Pilot waste water treatment tests were conducted through submerged membrane bioreactor (MBR) with two membrane modules namely hollow-fiber membrane module and flat-sheet membrane module. Comparative studies were also conducted with the two different MBR modules in terms of the optimal ratio of gas to permeated effluent, critical membrane flux, the quality of the permeate, membrane fouling and membrane cleaning. The results showed that the optimal ratio of gas to permeated effluent was 24 and 20 for hollow-fiber and flat-sheet membrane modules, respectively. The critical membrane flux, which was determined under the same aeration intensity, was 20 L·m^-2·h^-1 and 25 L·m^-2·h^-1 for hollow-fiber and flat-sheet membrane module respectively. There was no reasonable difference of the quality of permeate of the two modules. However, fiat-sheet module was more anti-fouling than hollow-fiber module; the flux recovery rate of flat-sheet module was larger than that of hollow-fiber module. Membrane flux of two modules could also be recovered by chemical cleaning with NaClO solution.
出处 《水处理技术》 CAS CSCD 北大核心 2009年第3期73-76,共4页 Technology of Water Treatment
关键词 MBR 临界膜通量 膜污染 膜清洗 中空纤维膜组件 平板式膜组件 MBR critical membrane flux membrane fouling membrane cleaning hollow-fiber membrane module flat-sheet membrane module
  • 相关文献

参考文献11

  • 1S Adham, et al. Feasibility of the membrane bioreactor process for water reclamation[J].Wat Sci Tech.,2001,43(10):20-32.
  • 2岑运华.膜生物反应器在污水处理中的应用[J].水处理技术,1991,17(5):318-323. 被引量:78
  • 3Yamamoto K, Hiasa M, Mahmood T, et al. Direct Solid-Liquid Separation Using Hollow Fiber Membrane in an Activated Sludge Aeration Tank[J].Wat Sci Tech., 1989,21:43 -54.
  • 4TATSUKI UEDA KLNJI HATA, et al. Effects of aeration on suction pressure in a submerged membrane bioreactor [J].Wat Res., 1997,31 (3):489-494.
  • 5HONG S P, BAE T H, TAK T M, et ol. Fouling control in activated sludge submerged hollow fiber membrane bioreactors [J].Desalination,2002,143:219-228.
  • 6Jungrnin L, Won-young A, Chung-hak L, et al. Comparison of the filtration characteristics between attached and suspended growth microorganisms in submerged membrane bioreactor [J]. Wat Res.,2001,35(10):2435- 2445.
  • 7Field R W, Wu D, Howell J A, et ol. Critical flux concept for microfiltration fouling [J].Journal of Membrane Science,1995, 100: 259- 272.
  • 8Cho B D, Fane A G. Fouling transients in nominally sub-critical flux operation of a membrane bioreactor [J].Journal of Membrane Science,2002,209:391-403.
  • 9Pierre L C, Bruce J, Chang I S, et al. Critical flux determination by the flux- step method in a submerged membrane bioreactor[J]. Journal of Membrane Science,2003,227:81- 93.
  • 10Defrance L, Jaffrin M Y. Comparison between filtrations at fixed trans-membrane pressure and fixed permeate flux: application to a membrane bioreactor used for wastewater treatment [J].Journal of Membrane Science, 1999,152:203 -210.

共引文献77

同被引文献78

引证文献8

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部