摘要 对(N+M)容错系统进行了初步的理论研究,分析了其可靠性,考察控制器可靠性和维修性对系统可用度的影响,并提出了改善系统可用度的措施. In this paper (N+M) fault tolerant systems are studied theoretically. The reliability of (N+M) FTS and the effect of reliability and maintai nability on its availability are analyzed. Some measures have been put forward to improve the availability of (N+M) FTS.
出处 《水电能源科学》 1998年第1期46-50,共5页 Water Resources and Power
关键词 水电站 容错系统 可靠性维修性 经济性 计算机 hydropower station, fault tolerant systems, reliability, maintainability, economics