对阳城—淮阴500kV交流线路加装串联电容补偿后的运行特性运行了计算分析,包括稳态工频电压升高、暂态工频电压升高、潮流计算和暂态稳定计算等,并得出了一些初步的结果。
A computation and analysis on the operating performance of the Yangcheng Huaiying 500 kV AC transmission line after an addition of series capacitor compensation including the computation of rise up of steady state and transient state power frequency voltage,power flow and transient stability are carriedout,and a preliminary result is obtained.
出处
《华东电力》
1998年第3期7-12,共6页
East China Electric Power
关键词
输电线路
交流线路
串补装置
series compensation power frequency over voltage power flow computation transient stability