期刊文献+

治疗股骨颈骨折的自锁空心加压防旋钉的研制 被引量:2

Development of self-locking cannulated compression anti-rotation blade for treatment of femoral neck fractures
原文传递
导出
摘要 目的探讨自锁空心加压防旋钉的设计特点和操作技术。方法采用7具尸体骨标本,截骨制作股骨颈骨折模型,按照设计的操作步骤应用白锁空心加压防旋钉进行固定,操作过程在X线监视下进行;固定后标本进行生物力学检测。结果自锁空心加压防旋钉紧密嵌入股骨近端,锁定时有加压作用,操作顺利,骨折固定稳定。结论自锁空心加压防旋钉设计先进,操作简单,可替代空心松质骨拉力螺钉。 Objective To develop self-locking cannulated compression anti-rotation blade and investigate its design characteristic and manipulation techniques. Methods Femoral neck fracture model was made by osteotomy on seven cadaver femurs and then fixed by self-locking cannulated compression anti-rotation blade under fluoroscopic guidance according to designed procedures. After fixation, biomechanic test was performed to evaluate fixation stability. Results Cannulated self-locking compression anti-rotation blade was tightly impacted in proximal femur and compression detected during the process of locking, with successful manipulation and stable fixation. Conclusion Because of advanced design characteristic and simple manipulation, self-locking cannulated compression anti-rotation blade can be a substitute for cannulated cancellous lag screw in treatment of femoral neck fractures.
出处 《中华创伤杂志》 CAS CSCD 北大核心 2009年第3期236-239,共4页 Chinese Journal of Trauma
基金 基金项目:国家“十一五”科技支撑规划资助项目(2007BA104B00) 国家重点基础研究发展计划资助项目(2005CB522604)
关键词 股骨颈骨折 骨折固定术 生物力学 Femoral neck fractures Fracture fixation, internal Biomechanics
  • 相关文献

参考文献8

  • 1姜保国,张殿英,付中国.股骨近端骨折的治疗[J].中华创伤骨科杂志,2004,6(5):484-487. 被引量:186
  • 2Tidermark J, Ponzer S, Svensson O, et al. Internal fixation compared with total hip replacement for displaced femoral neck fractures in the elderly. A randomised, controlled trial. J Bone Joint Surg (Br), 2003, 85(3) :380 -388.
  • 3Chen WC, Yu SW, Tseng IC, et al. Treatment of undisplaced femoral neck fractures in the elderly. J Trauma, 2005, 58 (5): 1035 - 1039.
  • 4Booth KC, Donaldson TK, Dai QG. Femoral neck fracture fixation: a biomechanical study of two cannulated screw placement techniques. Orthopedics, 1998, 21 ( 11 ) : 1173 - 1176.
  • 5Liebergall M, Ben - David D, Weil Y, et al. Computerized navigation for the internal fixation of femoral neck fractures. J Bone Joint Surg (Am) , 2006, 88 (8) : 1748 - 1754.
  • 6Maurer SG, Wright.KE, Kummer FJ, et al. Two or three screws for fixation of femoral neck fractures? Am J Orthop, 2003, 32 ( 9 ) : 438 - 442.
  • 7Baitner AC, Maurer SG, Hickey DG, et al. Vertical shear fractures of the femoral neck. A biomechanical study. Clin Orthop, 1999, (367) :300-305.
  • 8张殿英,姜保国,付中国.防旋股骨近端髓内钉治疗转子间骨折的初步疗效分析[J].中华创伤杂志,2007,23(2):91-93. 被引量:93

二级参考文献17

共引文献264

同被引文献18

  • 1Little NJ,Venna V,Fernando C,et al.A prospective trial comparing the Holland nailwith the dynamic hip screw in the treatment of inter trochanteric fractures of the hip.J Bone Joint Surg(Br),2008,90(8):1073-1078.
  • 2Leung WY,Tsang WL.Conventional muscle-reflection approach versus mini-lncision muscle-spliaing approach in dynamic hip screw fixation.J Orthop Surg(Hong Kong),2008,16(2):156-161.
  • 3童松林,徐仲棉,张主权.微创动力髋螺钉的研制[J].医疗设备信息,2007,22(10):17-18. 被引量:1
  • 4童松林,徐仲棉,陆文杰,陈建列,戴建萍,王以进.微创动力髋螺钉和动力髋螺钉治疗股骨颈基底部骨折的生物力学研究[J].中华创伤杂志,2007,23(11):860-863. 被引量:12
  • 5White JJ, Khan WS, Smitham PJ. Perioperative implications of surgery in elderly patients with hip fractures: an evidence -based review[ J]. J Perioper Pract, 2011,21 (6) : 192 - 197.
  • 6Cheng T, Zhang G, Zhang X. Review: minimally invasive versus con- ventional dynamic hip screw fixation in elderly patients with intertro- chanterie fractures : a systematic review and meta - analysis [ J ]. Surg Innov, 2011,18(2) :99 - 105.
  • 7Saarenpaa I, Heikkinen T, Ristiniemi J, et al. Functional comparison of the dynamic hip screw and the Gamma locking nail in trochanteric hip fractures : a matched - pair study of 268 patients [ J ]. Int Orthop. , 2009,33 ( 1 ) :255 - 260.
  • 8Gotfried Y, Cohen B, Rotem A. Biomechanical evaluation of the percu- taneous compression plating system for hip fractures[ J]. J Orthop Trau- ma, 2002,16(9) :644 -650.
  • 9Goffried Y. The lateral trochanteric waLL:a key element in the recon- struction of unstable pertrochanteric hip fractures[J]. Clin Orthop Relat Res, 2004,8(425) :82 -86.
  • 10Hughson J, Newman J, Pendleton RC. Hip fracture management for the hospital - based clinician : a review of the evidence and best practices [J].HospPract, 2011,39(1):52-61.

引证文献2

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部