介绍220 kV大型中心变电站的设计实例,并作出相应比较,其中220 kV设备的选用,采用小型化设计的中心站对全站占地面积的影响最大。着重分析了全GIS设备站的布置要求。
Design of the 220 kV large central substation was analyzed through comparison between an AIS substation and a miniature GIS substation. The equipment configuration of the miniature GIS substation was illuminated emphatically.
出处
《华东电力》
北大核心
2009年第2期261-264,共4页
East China Electric Power