期刊文献+

Ti基电极上光化学沉积Hg用于吸附溶出伏安法测定磺胺嘧啶 被引量:3

Determination of Sulfadiazine by Adsorptive Stripping Voltammetry Based on Photochemical Deposition of Mercury on Titanium Electrode
下载PDF
导出
摘要 该研究发现采用紫外光照射钛电极表面氧化钛层能够光催化还原Hg2+生成Hg微粒,在Ti基电极上光化学沉积Hg比电化学沉积Hg对磺胺嘧啶具有更强的吸附作用,基于光化学沉积Hg/Ti电极建立了一种吸附溶出伏安法测定磺胺嘧啶的方法。详细考察了溶液pH值、吸附富集时间、溶出起始电位、扫描速率等对测定的影响。结果表明,在pH2.0的B-R缓冲溶液中,磺胺嘧啶在0.48V左右处产生1个灵敏的氧化峰,其峰电流与磺胺嘧啶的浓度在1.2×10-8~1×10-6mol/L范围内呈良好的线性关系(r=0.9972),检出限达4.35nmol/L。 It was found that photochemical deposition of Hg occurred at the layer of TiO2 covering the surface of titanium electrode under UV irradiation, the adsorption of sulfadiazine on the photochemieally deposited Hg was stronger than that on the electrochemically deposited Hg, and a method for the determination of sulfadiazine was proposed by the adsorptive stripping vohammetry based on photochemical deposition of Hg on Ti electrode. The affecting factors such as pH, time of adsorption, starting potential of stripping process and scanning rate were studied. Results showed that a sensitive oxidation peak of sulfadiazine was obtained at about 0.48 V in B - R solution of pH 2.0, and the oxidation peak current was linearly proportional with the concentration of sulfadiazine over the range of 1.2 ×10^-8 to 1 ×10^-6 mol/L(r =0. 997 2) with a detection limit of 4.35 nmol/L.
出处 《分析测试学报》 CAS CSCD 北大核心 2009年第3期326-329,共4页 Journal of Instrumental Analysis
基金 湖南省科技厅资助项目(2007-JK-3057)
关键词 磺胺嘧啶 光化学还原 Hg/Ti电极 吸附溶出伏安法 sulfadiazine photochemical reduction Hg/Ti electrode adsorptive stripping vohammetry
  • 相关文献

参考文献14

二级参考文献43

  • 1谢玉璇,谢天尧,刘秋英,官春华.毛细管电泳-电导法分离检测磺胺嘧啶、磺胺甲嘧啶和磺胺二甲嘧啶[J].分析测试学报,2006,25(3):100-102. 被引量:20
  • 2特奈普西得 于竞 王进喜 白宏 等译.动物源性食品中药物残留分析方法[M].天津:科技翻译出版公司,1991.404.
  • 3陈义.毛细管电泳技术与应用[M].北京:化学工业出版社,2000..
  • 4汪尔康.21世纪的分析化学[M].北京:科学出版社,2001.269-284.
  • 5Litter M I. Heterogeneous photocatalysis: transition metal ions in photocatalytic systems[J]. Appl Catal B, 1999, 23(2): 89-114.
  • 6Namasivayam C, Periasamy K. Bicarbonate-treated peanut hull carbon for mercury (Ⅱ) removal from aqueous solution[J]. Water Res, 1993, 27(11): 1663-1668.
  • 7Osteen A B, Bibler J. Treatment of radioactive laboratory waste for mercury removal[J]. Water Air Soil Pollut, 1991, 56(1): 63-74.
  • 8Ghazy S E. Removal of cadmium, lead, mercury, tin,antimony, and arsenic from prinking and seawaters by colloid precipitate flotation [J]. Sep Sci Technol,1995, 30(3): 933-947.
  • 9Fox M A, Dulay M T. Heterogeneous photocatalysis[J]. Chem Rev, 1993, 93(1): 341-357.
  • 10Linsebigler A L, Lu G, Yates J T. Photocatalysis on TiO2 surface: principles mechanisms and selected results[J]. Chem Rev, 1995, 95(3): 735 - 758.

共引文献148

同被引文献26

  • 1汪洁,魏然.反相高效液相色谱法测定复方磺胺嘧啶滴鼻液中磺胺嘧啶和盐酸麻黄碱含量[J].中南药学,2006,4(6):421-423. 被引量:10
  • 2Berzas J J, Nevado G, Castaneda Penalvo F J, et al. Determination of sulfametoxasole, sulfadiazine and associated compounds in pharmaceutical preparations by capillary zone electrophoresis[J]. Journal of Chromatography A, 2001,918(1): 205-210.
  • 3Espinosa-Mansilla A, Salinas F, De Orbe Paya I. Simultaneous determination of sulfadiazine, doxycycline, furaltadone and trimethoprim by partial least squares multivariate calibration[J]. Analytica C himica Acta, 1995,313(1-2), 20:103-112.
  • 4Kunihiro Kishida, Naoto Furusawa. Matrix solid-phase dispersion extraction and high-performance liquid chromatographic determilation of residual sulfonamides in chicken[J]. Journal of Chromatography A, 2001, 937(1-2): 49-55.
  • 5Titus A M Msagati, Catherine Ngila J. Voltammetric detection of sulfonamides at a poly(3-methylthiophene) electrode[J]. Talanta, 2002, 58(3): 605-610.
  • 6Guzm a n-V a zquez de Prada A, Reviejo A J, Pingarr o n J M. A method for the quantification of low concentration sulfamethazine residues in milk based on molecularly imprinted clean-up and surface pre-concentration at a Nation-modified glassy carbon electrode[J]. Journal of Pharmaceutical and Biomedical Analysis, 2006, 40(2):281-286.
  • 7Evtugyn G A, Stoikov I I, Beljyakova S V, et al. Ag selective electrode based on glassy carbon electrode covered with polyaniline and thiacalixarene as neutral carrier[J]. Talanta, 2007, 71(4): 1720-1727.
  • 8Titus A, Msagati M, Catherine Ngila J. Vohammetric detection of sulfonamides at a poly (3-methylthiop-hene) electrode[J]. Talanta, 2002, 58(3): 605-610.
  • 9刘宏英.高效液相色谱法测定联磺甲氧苄啶片中磺胺嘧啶含量[J].中国药业,2007,16(24):29-29. 被引量:5
  • 10Horie M,Kobayashi H, Ishii R. Simple and rapid microbiolog- ical method for determination of residual antibacterials in meat [J]. Shokuhin Eiseigaku Zasshi,2008,493 : 168-176.

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部