摘要
对云南省生产的86批注射用青霉素钠、75批硫酸卡那霉素注射液和26批盐酸林可霉素注射液进行了中国药典规定的家兔法与细菌内毒素检测法之间的对比考察,两者的符合率均为100%.
Reported the comparision results between the bacterial endotoxins test and the pyrogen test of 86 lots of Benzylpenicillin Sodium for injection,75 lots of Kanamycin Sulfate injection and 26 lots of Lincomycin Hydrochloride injection.The coincidental rate was 100%.
出处
《云南大学学报(自然科学版)》
CAS
CSCD
1998年第2期148-150,共3页
Journal of Yunnan University(Natural Sciences Edition)
关键词
青霉素钠
抗生素注射剂
细菌内毒素
热原检查法
benzylpenicinllin sodium for injection,kanamycin sulfate injection,lincomycin hydrochloride injection,bacterial endotoxins,pyrogen test