摘要 介绍了某电厂一期工程2台600MW超临界机组汽轮机中压缸启动的过程和特点,详细分析了启动过程中存在的故障并提出了具体的处理措施。最后指出,中压缸启动方式可使机组的启动更安全、经济。 The process and features of start-up through intermediate pressure ( IP ) cylinder of two 600 MW units in some power plant project phase I were presented. The faults occurred in the process of start-up through IP cylinder were analyzed in detail, and the relevant treatment measures were proposed. At last, it was pointed out that the tart-up through IP cylinder is a safer and more economic way for unit start-up.
作者 何辉 吴强
出处 《华电技术》 CAS 2009年第3期5-8,共4页 HUADIAN TECHNOLOGY
关键词 超临界机组 汽轮机 中压缸启动 故障分析 处理 super-critical unit steam turbine start-up through intermediate pressure (IP) cylinder fault analysis treatment