摘要
针对火电厂汽轮发电机由于漏氢监测装置设备复杂、不安全等因素,严重影响机组安全及经济运行的问题,简要分析存在的问题及原因,并提出了具体解决方案。改造后的运行情况表明,效果明显,对汽轮发电机漏氢监测提供实例,有力保障了设备安全稳定运行。
As for insecurity factors in leakage monitoring system which influence the sable and economic operation, solutions were put forward. The fact shows that the reform is effective and useful to stable operation.
出处
《江西电力》
2009年第1期29-31,共3页
Jiangxi Electric Power
关键词
氢气
漏氢
传感器
多通道
hydrogen
hydrogen leakage
sensor
multi-channel