摘要 可调谐激光光谱(TDLAS)技术利用激光管的波长扫描实现痕量气体吸收曲线的二次谐波检测,具有响应时间短、检测灵敏度高、精度高等优点。但实际应用条件分析结果表明,烟道气在线检测中存在外界环境和系统本身引入的噪声。为了实现TDLAS检测方法的高精度、高灵敏度等优势,本文提出在检测系统中加入温度反馈,以减少高温环境带来的干扰,设计并采用双光路扣除背景,消除颗粒物及背景吸收干扰以及采用对激光管驱动电流进行高频调制来抑制系统噪声等3条主要的降噪途径。理论分析表明,这些措施可以降低环境干扰及系统噪声影响,有效提高检测精度。 As a new trace gas detection technique, tunable diode laser absorption spectroscopy (TDLAS) can realize the second-harmonic detection of the trace gases absorption curve by using the wavelength scanning of the laser, it has the following advantages such as short respond time, high sensitivity and high precision and so on. But the practical application condition results indicate that environment interference and system noise can't be ignored in the in-situ gas monitoring system. The three major noise reduction channels such as adding temperature feedback in the detection system to reduce interference from high-temperature environment, design and use a dual optical path of background deduction to eliminate particulate matter and background absorption interference, using the application of the laser drive current to carry out high-frequency modulation system to suppress noise are introduced in this paper. Theory analysis shows that these measures can reduce the environmental interference and system noise, and also can improve detection accuracy effectively.
作者 杜磊 汪曣
出处 《新技术新工艺》 2009年第2期51-53,共3页 New Technology & New Process
关键词 可调谐二极管激光吸收光谱 背景扣除 二次谐波 温度反馈 TDLAS Background deduction Second-harmonic Temperature feedback
  • 相关文献

参考文献4

二级参考文献26

  • 1司福祺,刘建国,刘文清,王亚萍,张玉钧,黄书华,方武,汪世美.基于气体相关滤波技术的非分散红外Co气体监测系统的研究[J].量子电子学报,2004,21(4):425-428. 被引量:16
  • 2[1]D.P.Leleux,R.Claps,W.Chen,et al..Applications of Kalman filtering to real-time trace gas concentration measurements.Applied Physics B-Lasers and Optics,2002,74(1): 85~93.
  • 3[2]H.Riris,C.B.Carlisle,R.E.Warren,et al..Signal processing strategies in tunable diode laser spectrometers.Spectrochimica Acta Part a-Molecular and Biomolecular Spectroscopy,1996,52(8): 843~849.
  • 4[3]A.N.Dharamsi,P.C.Shea,and A.M.Bullock.Reduction of effects of Fabry-Perot fringing in wavelength modulation experiments.Applied Physics Letters,1998,72(24): 3118~3120.
  • 5[4]G.Durry,I.Pouchet,N.Amarouche,et al..Shot-noise-limited dual-beam detector for atmospheric trace-gas monitoring with near-infrared diode lasers.Applied Optics,2000,39(30): 5609-5619.
  • 6[5]P.Y.Chien.A balanced dual-photodetector optical receiver for daylight operation.Review of Scientific Instruments,1991,62(4): 1098~1099.
  • 7[6]S.E.Plunkett,M.S.Zahniser,M.E.Parrish,et al..Infrared line strengths and pressure broadening coefficients in the nu(12) vibrational band of hydrazine measured by infrared tunable diode laser spectroscopy.Journal of Molecular Spectroscopy,2002,211(2): 241~247.
  • 8[7]C.Claveau,A.Henry,M.Lepere,et al..Narrowing and broadening parameters for H2O lines in the nu(2) band perturbed by nitrogen from Fourier transform and tunable diode laser spectroscopy.Journal of Molecular Spectro- Scopy,2002,212(2): 171~185.
  • 9[8]A.Kissel,H.D.Kronfeldt,B.Sumpf,et al..Tikhomirov.Line broadening and line shift of H2S absorption lines in the v(2) band - collisions with H2O and Ar in a three component mixture.Journal of Quantitative Spectro- scopy & Radiative Transfer,2001,69(5): 573~583.
  • 10[9]L.R.Brown and C.Plymate.Experimental line parameters of the oxygen A band at 760 nm.Journal of Molecular Spectro- scopy 199(2),166-179 (2000).