摘要 波状翅片扁平管,即单排管是直接空冷凝汽器的一种基本换热元件。单排管外空气侧的流动和传热性能研究,对于直接空冷凝汽器的优化设计和安全运行具有重要的意义。在不同迎面风速下,对国产空冷单排管空气侧进行三维数值模拟,并对速度场、温度场进行分析和研究,拟合出单排管阻力和传热系数随迎面风速变化的计算公式,为直接空冷系统的优化设计提供帮助。 Wavy-finned flattened tube, which is usually called single row tube, is one kind of basic heat exchange element for direct air cooled condensers. The research on the flow and heat transfer performance outside single row tube is of great important for the optimal design and safe operation of air cooled condensers. Under different frontal wind velocity, the 3 dimensional airside of domestic air cooling single row tube is simulated; the flow field and temperature field are analyzed and studied. Data regressions give the equations of pressure drop and heat transfer coefficient with frontal wind velocity. It offers good help for the optimal design of direct air cooling system.
出处 《电站系统工程》 北大核心 2009年第2期19-21,共3页 Power System Engineering
关键词 单排管 空冷凝汽器 数值模拟 优化设计 single row tube air cooled condenser numeral simulation optimal design
  • 相关文献

参考文献5

  • 1四川川分换热器有限公司.空气换热器换热表面空气侧传热与阻力特性实验报告[R].2006.
  • 2四川川分换热器有限公司.空气换热器翅片表面空气传热与阻力特性的试验研究[R].西安交通大学,2007.
  • 3胡三季.钢制双列滴型管套矩形翅片空冷元件传热及阻力性能试验研究报告[R].西安:西安热工研究院有限公司,2006.
  • 4Kroger, Detlv G. Air-cooled heat exchangers and cooling tower: thermal-flow performance and design [M]. Penwell Corporation, 2004.
  • 5Tao Y B, He Y L, Wu Z G, et al. Three-dimensional numerical study and field synergy principle analysis of wavy fin heat exchangers with elliptic tubes [J]. Int. J. of Heat and Fluid Flow, 2007, (2): 1- 14.

共引文献8

同被引文献57

引证文献9

二级引证文献38

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部