A super-high angular resolution principle for coded-mask X-ray imaging beyond the diffraction limit of a single pinhole

A super-high angular resolution principle for coded-mask X-ray imaging beyond the diffraction limit of a single pinhole
下载PDF
导出
摘要 High angular resolution X-ray imaging is always useful in astrophysics and solar physics. In principle, it can be performed by using coded-mask imaging with a very long mask-detector distance. Previously, the diffraction-interference effect was thought to degrade coded-mask imaging performance dramatically at the low energy end with its very long mask-detector distance. The diffraction-interference effect is described with numerical calculations, and the diffraction-interference cross correlation reconstruction method (DICC) is developed in order to overcome the imaging performance degradation. Based on the DICC, a super-high angular resolution principle (SHARP) for coded-mask X-ray imaging is proposed. The feasibility of coded mask imaging beyond the diffraction limit of a single pinhole is demonstrated with simulations. With the specification that the mask element size is 50 × 50 μm^2 and the mask-detector distance is 50 m, the achieved angular resolution is 0.32arcsec above about 10keV and 0.36arcsec at 1.24keV (λ = 1 nm), where diffraction cannot be neglected. The on-axis source location accuracy is better than 0.02 arcsec. Potential applications for solar observations and wide-field X-ray monitors are also briefly discussed. High angular resolution X-ray imaging is always useful in astrophysics and solar physics. In principle, it can be performed by using coded-mask imaging with a very long mask-detector distance. Previously, the diffraction-interference effect was thought to degrade coded-mask imaging performance dramatically at the low energy end with its very long mask-detector distance. The diffraction-interference effect is described with numerical calculations, and the diffraction-interference cross correlation reconstruction method (DICC) is developed in order to overcome the imaging performance degradation. Based on the DICC, a super-high angular resolution principle (SHARP) for coded-mask X-ray imaging is proposed. The feasibility of coded mask imaging beyond the diffraction limit of a single pinhole is demonstrated with simulations. With the specification that the mask element size is 50 × 50 μm^2 and the mask-detector distance is 50 m, the achieved angular resolution is 0.32arcsec above about 10keV and 0.36arcsec at 1.24keV (λ = 1 nm), where diffraction cannot be neglected. The on-axis source location accuracy is better than 0.02 arcsec. Potential applications for solar observations and wide-field X-ray monitors are also briefly discussed.
出处 《Chinese Journal of Astronomy and Astrophysics》 CSCD 2009年第3期333-340,共8页 中国天文和天体物理学报(英文版)
基金 Supported by the National Natural Science Foundation of China.
关键词 INSTRUMENTATION high angular resolution - techniques image processing - telescopes instrumentation high angular resolution - techniques image processing - telescopes
  • 相关文献

参考文献13

  • 1Aschenbach, B. 1985, Reports on Progress in Physics, 48, 579
  • 2Fenimore, E. E., & Cannon, T. M. 1978, Applied Optics, 17, 337
  • 3Gehrels, N. 2004, New Astronomy Reviews, 48,431
  • 4Gorenstein, P. 2007, Advances in Space Research, 40, 1276
  • 5Lindsey, C. A. 1978, J. Opt. Soc. Am., 68, 1708
  • 6Prince, T. A., Hurford, G. J., Hudson, H. S., & Crannell, C. J. 1988, Solar Phys., 118, 269
  • 7Skinner, G. K. 2004, New Astronomy Reviews, 48, 205
  • 8Struder, L. 2000, Nucl. Instr. and Meth. A, 454, 73
  • 9The XEUS Telescope Working Group, 2001, X-ray evolving universe spectroscopy-the XEUS telescope, ESA SP-1253
  • 10Treis, J., Fischer, E, Halker, O., et al. 2006, Nucl. Instr. and Meth. A, 568, 191