摘要
简要介绍了AN型静叶可调轴流引风机的结构,对AN型静叶可调轴流引风机在运行过程中的故障原因进行了分析,并针对所出现的故障实施了相应的技术改造处理,实践证明,改进后的风机运行效果良好。
This paper briefly introduces the structure of the AN type stationary blade adjustable axial-flow induced fan. The fault reason of AN type stationary blade adjustable axial-flow induced fan during operation is analyzed. Moreover, a series of improvement and treatment in technology are carried out in terms of fault. The practice proves that the operation effect is good after improvement.
出处
《风机技术》
2009年第1期66-68,82,共4页
Chinese Journal of Turbomachinery
关键词
轴流式引风机
故障
分析
处理
axial-flow induced fan
fault
analysis
treatment