期刊文献+

多功能热泵空调热水器的模拟与实验分析 被引量:7

Simulation and experimental study on a multi-function heat pump air-conditioner integrated water heater
下载PDF
导出
摘要 为了降低家庭热水能耗,提高设备利用率,减少初投资,设计了一种兼有空调与热水供给功能的多功能热泵空调热水器.对压缩机额定功率1.3 kW、热水容量60 L的样机进行了热泵制热水模式的性能模拟与实验研究.实验结果显示,在8℃的环境温度下将水加热到50℃,系统能效比为2.2.通过模拟进行系统优化,提出了进一步提高系统整体性能的措施;循环水流量由0.06 L/s增加到0.24 L/s,能效比提高16.8%;冷凝器面积增大一倍,能效比提高16%. A multi-function heat pump device, used for both air conditioning and water heating was developed to decrease the energy consumption of water heating, improve the utilization ratio of equipments and decrease the first cost. A prototype which has a compressor with the rated capacity of 1.3 kW and the water volume of 60 L was designed. Simulation and experiments were carried out in the working mode of heat pump water heating. Results show that the energy efficiency rate ( EERw) of the proto-type is 2. 2 for heating water up to 50℃ in winter when at ambient temperature of 8℃. Measures of further performance improvement are proposed. Optimization results show that, the change of water flow rate from 0. 06 l/s to 0. 24 l/s can increase EERw by 16. 8% ; doubling the heat-transfer area of condenser can increase EERw by 16%.
出处 《哈尔滨工业大学学报》 EI CAS CSCD 北大核心 2009年第2期211-213,共3页 Journal of Harbin Institute of Technology
基金 国家高技术研究发展计划资助项目(2007AA05Z434)
关键词 空调 热泵热水器 多功能 节能 能效比 air-conditioner heat pump water heater multi-function heat pump energy efficiency rate
  • 相关文献

参考文献4

  • 1JIE Ji, CHOW Tin-tai, GANG Pei, et al. Domestic airconditioner and integrated water heater for subtropical climate [ J ]. Applied Thermal Engineering, 2003, 23 (5) :581 -592.
  • 2李舒宏,武文彬,张小松,殷勇高.太阳能热泵热水装置试验研究与应用分析[J].东南大学学报(自然科学版),2005,35(1):82-85. 被引量:42
  • 3ROUSSEAU P G, ELDIK V M, GREYVENSTEIN G P. Detailed simulation of fluted tube water heating condensers [ J ]. International Journal of Refrigeration, 2003, 26 (2) : 232 - 239.
  • 4XU G Y, ZHANG X S, DENG S M. A simulation study on the operating performance of a solar-air source heat pump water heater [ J ]. Applied Thermal Engineering, 2006, 26 ( 11 - 12) : 1257 - 1265.

二级参考文献9

  • 1Huang B J, Chyng J P. Integral-type solar-assisted heat pump water heater[ J ]. Renewable Energy, 1999,16(2) :731 -734.
  • 2Huang B J, Chyng J P. Long-term performance of solar-assisted heat pump water heater [ J ]. Renewable Energy, 2004, 29(4) : 633 -639.
  • 3Chyng J P, Lee C P, Huang B J. Performance analysis of a solar-assisted heat pump water heater [ J ]. Solar Energy, 2003, 74( 1 ) :33 -44.
  • 4Ji Jie. Domestic air-conditioner and integrated water heater for subtropical climate [ J ]. Applied Thermal Engineering, 2003, 23(5) :581 -592.
  • 5Chaichana C, Lu Aye. NaaLral working fluids for solarboosted heat pumps [ J ]. International Journal of Refrigeration. 2003. 26 ( 6 ) :637 - 643.
  • 6Hawlader M N A, Chou S K, Ullah M Z. The performance of a solar assisted heat pump water heater system[J]. Applied Thermal Engineering, 2001, 21 ( l0 ) :1049 - 1065.
  • 7冒东奎.太阳能热泵热水器性能的模拟研究[J].宁夏工学院学报(自然科学版),1997,9(1):42-49. 被引量:6
  • 8旷玉辉,王如竹.太阳能热泵[J].太阳能,2003(2):20-24. 被引量:37
  • 9余乐渊,赵军,朱强,张春雷.压缩式热泵热水器实验研究及性能分析[J].能源工程,2003,23(4):56-58. 被引量:27

共引文献41