目的:建立HPLC法测定丹皮酚滴丸含量,并对测量不确定度进行分析。方法:通过建立HPLC法测定丹皮酚含量的数学模型,找出影响不确定度的主要因素并对各不确定度分量进行评估。结果:计算各变量不确定度及合成不确定度,本次丹皮酚滴丸含量测定结果为164.77mg.g-1,其扩展不确定度为6.00mg.g-1(k=2)。结论:本试验建立的不确定度评估方法适用于HPLC法测定固体制剂有效成分含量的不确定度评定。
Objective:To establish a method for uncertainty analysis in HPLC determination for Paeonol Dripping Pills.Methods:The calculation formula of uncertainty was deduced in the procedure of determining Paeonol in Dripping Pills.Results:Each component of uncertainty was calculated among the procedures,and combined uncertainty was finally obtained.The content of Paeonol in Dripping Pills is 164.77 mg·g-1,and the expanded uncertainty was 6.00 mg·g-1(k=2).Conclusion:The mathematic model established here is suitable for uncertainty analysis for HPLC assay.
出处
《药物分析杂志》
CAS
CSCD
北大核心
2009年第3期472-474,共3页