电磁式电压互感器铁芯饱和引起的铁磁谐振过电压分为分频谐振、基波谐振,高次谐波谐振过电压。文章提出其判别方法,并给出实例。
Component harmonics and fundamental wave and high hannonics ferromagnetic resonance overroltage by ferro core saturation of electro - magnet type TV, This paper diagnosis method are put forward, corresponding example is given.
出处
《安徽冶金科技职业学院学报》
2009年第1期38-40,共3页
Journal of Anhui Vocational College of Metallurgy and Technology
关键词
TV
铁磁谐振
过电压
判定
TV
ferromagnetic resonance
overvoltage