摘要 目的:运用多焦视网膜电流图(multifocal electroretinogram,mERG)评价弱视患者的局部视网膜功能。方法:采用103个六边形刺激图形,记录30例弱视患者mERG的b波振幅密度值在六环的表现。结果:47只弱视眼mERG在1环和2环b波振幅分轻、中、重不同程度下降,三维(3D)图显示中央局部视网膜功能降低,其中14只眼的3D图表现中心峰偏位现象。结论:多焦ERG是一种评价局部视网膜功能的新技术,对弱视的诊断和分类以及指导临床治疗具有重要意义。 Objective: To evaluate the local retinal function of patients with amblyopia by muhifocal electroretinogram. Methods: Used 103 the hexagon stimulating graphics, record performance of mERG amplitude of the b-wave density of 30 cases with amblyopia in the six central. Results: The b-wave amplitude of 47 visually-impaired eyes mERG in Central 1 and Central 2,drop at light, medium and heavy to varying degrees, Map three-dimensional(3D) showed that local central retinal function level down, the 3D map of 14 eyes expressed Center-peak-phenomenon. Conclusion: mERG is a kind of new technology to evaluate the local retinal function, it has great significance on the classification and diagnosis of amblyopia, as well as to guide clinical treatment.
机构地区 深圳市眼科医院
出处 《中国当代医药》 2009年第4期19-20,共2页 China Modern Medicine
关键词 弱视:多焦视网膜电流图 Amblyopia Muhifocal electroretinogram
  • 相关文献

参考文献3

二级参考文献19

  • 1李建东.弱视的图形视网膜电图研究[J].中华眼科杂志,1989,25(3):138-140.
  • 2S Parks,D Keating,TH Williamson,et al.Functional imaging of the retina using the multifocal electroretinograph:a control study.Br J Ophthalmol,1996,80:831-834.
  • 3Hood DC,Holopigian K,Greestein V,et al.Assessment of local retinal function in patients with retinits pigmentosa using the multi-focal ERG technique.Vision Res,1998,38:163-179.
  • 4Sutter E,Eran D.The field topography of ERG components-Ⅰ.The photoic luminance response.Vision Res,1992,32:433-446.
  • 5Bearse MA Jr,Sutter E.Imaging localized retinal dysfunction with the mulifocal electroretinogram.J Opt Soc Am A,1996,13:634-640.
  • 6Curcio CA,Sloan KR,Kalina RE,et al.Human photoreceptor topography.J Comp Neurol,1990,292:497-523.
  • 7Maffei L, Fiorentini A. Electroretinopgraphic responses to alternating gratings before and after.section of the optic nerve Science. 1981, 211 (27): 953.
  • 8Maffei L, Fiorentini A, Bisti S. Pattern ERG in monkey after section of the optic nerve. Exp Brain Res. 1985, 59:423.
  • 9Arden GB, Vaegan, hogg CR. Clinical and experimental evidence that the pattern electroretinogram (PERG) is generated in more proximal retinal layers than the focal electroretinogram (FERG). Ann NY Acd Sci, 1982, 580:601.
  • 10Drasdo N. Cox W, Thompson DA. The effects of image degradation on retinal illuminance and pattern responses to.checker stimuli. Doc Ophthalmol. 1897. 66: 267.