期刊文献+

防爆发电机三相突然短路试验探讨 被引量:2

Approach on Sudden Short-circuit Test for Explosion Protected Three-phase Generator
下载PDF
导出
摘要 防爆发电机突然短路试验是为了考核电机的抗短路故障能力,在防爆发电机突然短路时,高温和热量(弧光短路)会造成壳体烧穿现象。目前国家还没有防爆发电机三相突然短路试验的相关标准,文章针对防爆发电机三相突然短路故障危害的分析,探讨了防爆发电机突然短路试验的相关依据,提出了防爆发电机三相突然短路试验的新方法。 The ability against short - circuit fault of explosion protected generator is verified by sudden short - circuit test. While the generator is in the case of suddenly - applied short circuit, it would be caused bread- through by the high temperature or arc light short circuit. At the present time, there is no standard for sudden short - circuit test on Ex generator. It approaches on the correlative gist to sudden short - circuit test on Ex generator by analyzing the dangerous and risk caused by suddenly - applied short circuit fault on the three phases of Ex generator. A new method on such test has put forward.
出处 《电气防爆》 2009年第1期5-9,共5页 Electric Explosion Protection
关键词 防爆发电机 突然短路 试验 explosion protected generator suddenly- applied short circuit testing
  • 相关文献

参考文献6

  • 1GB 755--2000,旋转电机定额和性能[S].
  • 2GB 3836.1-2000,爆炸性气体环境用电气设备通用要求[S].
  • 3GB 3836.2-2000,爆炸性气体环境用电气设备隔爆型电气设备"d""[S].
  • 4GB/T 1029-2005,三相同步电机试验方法[S].
  • 5GB/T 7064-2002,透平型同步发电机技术要求[S].
  • 6许实章.电机学[M].北京:机械工业出版社,1996.