期刊文献+

Diffusion-weighted Single-shot Echo Planar MR Imaging of Normal Human Prostate Using Different b Values

Diffusion-weighted Single-shot Echo Planar MR Imaging of Normal Human Prostate Using Different b Values
下载PDF
导出
摘要 This study examined the effect of different b values on diffusion-weighted MR imaging (DWI) of human prostate by using single-shot spin echo echo planar imaging (SE-EPI) sequences, observed the normal appearances and measured apparent diffusion coefficient (ADC) values in anatomical regions of normal prostate. Twenty-four healthy volunteers (mean age: 32 y) were studied by using a 1.5T system with a phased array surface multicoil. Two kinds of single-shot SE-EPI sequence were used to perform DWI in the prostate in volunteers, with five b values being 0, 30, 300, 500 to 1000 s/mm2. The image quality with different imaging parameters was analyzed and the ADC values in anatomical regions of normal prostate were measured. DWI of prostate was successfully obtained in all volunteers. The images were of good quality, without artifacts containing pixels within the prostate. The contrast was good between the different anatomical regions of the prostatic gland, i.e., the peripheral zone (PZ), which exhibited higher signal intensity, and the central gland (CG). Signal intensity contrast was related to the magnitude of b values. The ADC values in PZ and CG were (1.27±0.22)×10-3 mm2/s and (1.01±0.17)×10-3 mm2/s,respectively. The ADC values were found to be significantly higher in PZ than in CG (P〈0.05, paired t-test). Significant differences were found between the slice-selecting component and both the read-out and phase-encoding components of the ADC values. It is concluded that SE-EPI is a suitable DWI sequence for human prostate. The contrast between PZ and CG is good when b values are low, while the diffusion and ADC values are accurate when b values are high. ADC values are higher in PZ than in CG in normal prostate. Diffusional anisotropy is present in normal prostatic tissue. This study examined the effect of different b values on diffusion-weighted MR imaging (DWI) of human prostate by using single-shot spin echo echo planar imaging (SE-EPI) sequences, observed the normal appearances and measured apparent diffusion coefficient (ADC) values in anatomical regions of normal prostate. Twenty-four healthy volunteers (mean age: 32 y) were studied by using a 1.5T system with a phased array surface multicoil. Two kinds of single-shot SE-EPI sequence were used to perform DWI in the prostate in volunteers, with five b values being 0, 30, 300, 500 to 1000 s/mm2. The image quality with different imaging parameters was analyzed and the ADC values in anatomical regions of normal prostate were measured. DWI of prostate was successfully obtained in all volunteers. The images were of good quality, without artifacts containing pixels within the prostate. The contrast was good between the different anatomical regions of the prostatic gland, i.e., the peripheral zone (PZ), which exhibited higher signal intensity, and the central gland (CG). Signal intensity contrast was related to the magnitude of b values. The ADC values in PZ and CG were (1.27±0.22)×10-3 mm2/s and (1.01±0.17)×10-3 mm2/s,respectively. The ADC values were found to be significantly higher in PZ than in CG (P〈0.05, paired t-test). Significant differences were found between the slice-selecting component and both the read-out and phase-encoding components of the ADC values. It is concluded that SE-EPI is a suitable DWI sequence for human prostate. The contrast between PZ and CG is good when b values are low, while the diffusion and ADC values are accurate when b values are high. ADC values are higher in PZ than in CG in normal prostate. Diffusional anisotropy is present in normal prostatic tissue.
出处 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2008年第6期737-740,共4页 华中科技大学学报(医学英德文版)
基金 supported by a grant from Key Project of Science and Technology Research of Hubei Province of China (No. 2005AA304B08).
关键词 PROSTATE magnetic resonance imaging diffusion-weighted imaging b value apparentdiffusion coefficient prostate magnetic resonance imaging diffusion-weighted imaging b value apparentdiffusion coefficient
  • 相关文献

参考文献10

  • 1Koh D M,Takahara T,Imai Y et al.Practical aspects of assessing tumors using clinical diffusion-weighted imag-ing in the body[].Magn Reson Med Sci.2007
  • 2Lytton B.Demongraphic factors in benign prostatic hy-perplasia[].Prostate The.1989
  • 3Cercignani M,Horsfield MA.The physical basis of diffusion-weighted MRI[].Journal of the Neurological Sciences.2001
  • 4Sorensen,AG,Wu,O,Copen,WA.Human acute cerebral ischemia: detection of changes in water diffusion anisotropy by using MR imaging[].Radiology.1999
  • 5Castillo M,Smith JK,Kwock L,et al.Apparent diffusion coefficients in the evaluation of high-grade cerebral gliomas[].American Journal of Neuroradiology.2001
  • 6Mascalchi M,Filippi M,Floris R, et al.Diffusion-weighted MR of the brain: methodology and clinical application[].Radiologia Medica.2005
  • 7Colagrande S,Carbone SF,Carusi LM,et al.Magnetic resonance diffusion-weightedi maging:extraneurological application[].Radiologia Medica.2006
  • 8Jemal A,,Thomas A,Murray T, et al.Cancer statistics[].CA A Cancer Journal for Clinicians.2002
  • 9Issa B.In vivo measurement of the apparent diffusion coefficient in normal and malignant prostatic tissues using echo-planar imaging[].Journal of Magnetic Resonance Imaging.2002
  • 10Sato C,Naganawa S,Nakamura T,et al.Differentiation of non-cancerous tissue and cancer lesions by apparent diffusion coeffi-cient values in transition and peripheral zones of the prostate[].Journal of Magnetic Resonance Imaging.2005