期刊文献+

腹部肿瘤精确放疗准确性的影响因素 被引量:1

Factors that affect the accuracy in the precise radiotherapy for abdomen tumors
原文传递
导出
摘要 精确放疗在临床已得到广泛应用,但在实施过程中存在很多影响放疗准确性的因素,最终可明显影响治疗效果。腹部肿瘤精确放疗过程中存在不确定性因素,总结以往的研究数据,分析呼吸运动、摆位、体位及固定技术、体重、肿瘤自身退缩及肿瘤周围器官运动与充盈等情况对精确放疗的影响,有助于对临床工作中要注意的问题进行探讨。 The precise radiotherapy has been widely used in the clinics. But there are many factors that affect the accuracy in the course of implementation. Finally the effect of radiotherapy is affected. These factors are reviewed. And the previous research data about the abdomen tumors is summed up. Also how the accuracy was affected by the respiratory movement, positioning, position fixed technology, weight, retraction and motion of the tumor and the situation of surrounding organs will be analyzed. At last, how to avoid these errors in clinics will be discussed.
出处 《国际放射医学核医学杂志》 2008年第6期360-362,378,共4页 International Journal of Radiation Medicine and Nuclear Medicine
基金 国家自然科学基金(10705016) 2.江苏省自然科学基金(BK2007553)
关键词 腹部肿瘤 放射疗法 不确定性 Abdomen neoplasms Radiotherapy Inaccuracy
  • 相关文献

参考文献22

  • 1Bussels B, Go ethals L, Feron M, et al. Respiration-induced movement of the upper abdominal organs: a pitfall for the threedimensional conformal radiation treatment of pancreatic cancer[J]. Radiother Oncol, 2003, 68(1): 69-74.
  • 2Kim YS, Park SH, Ahn SD, et al. Differences in abdominal organ movement between supine and prone positions measured using four-dimensional computed tomography[J]. Radiother Oncol, 2007, 85(3): 424-428.
  • 3Jacobs I, Vanregemorter J, Scalliet P. Influence of respiration on calculation and delivery of the prescribed dose in external radiotherapy[J]. Radiother Oncol, 1996, 39(2): 123-128.
  • 4Keall PJ, Mageras GS, Baiter JM, et al. The management of respiratory motion in radiation oncology report of AAPM Task Group 76[J]. Med Phys, 2006, 33(10): 3874-3900.
  • 5Simon L, Giraud P, Servois V, et al. Comparative study and clinical implementation of two breathing-adapted radiotherapy techniques: dosimetric benefits for lung cancer treatment[J]. Cancer Radiother, 2006, 10(6-7): 370-376.
  • 6Korreman SS, Juhler-Nottrup T, Boyer AL. Respiratory gated beam delivery cannot facilitate margin reduction, unless combined with respiratory correlated image guidance [J]. Radiother Oncol, 2008, 86(1): 61-68.
  • 7Mutaf YD, Brinkmann DH. Optimization of internal margin to account for dosimetric effects of respiratory motion [J]. Int J Radiat Oncol Biol Phys, 2008, 70(5): 1561-1570.
  • 8Hurkmans CW, Remeijer P, Lebesque JV, et al. Set-up verification using portal imaging; review of current clinical practice[J]. Radiother Oncol, 2001, 58(2): 105-120.
  • 9Hoogeman MS, van Herk M, de Bois J, et al. Strategies to reduce the systematic error due to tumor and rectum motion in radiotherapy of prostate cancer [J]. Radiother Oncol, 2005, 74(2): 177-185.
  • 10邱梅.腹部肿瘤放疗使用固定器价值的探讨[J].现代肿瘤医学,2004,12(6):580-581. 被引量:15

二级参考文献10

  • 1Skala M, Berry M, Duchesne G, et al. Australian and New Zealand three-dimensional conformal radiation therapy consensus guidelines for prostate cancer. Australasian Radiology,2004,48:493-501.
  • 2Weber DC, Nouet P, Rouzaud M, et al. Patient positioning in prostate radiotherapy: is prone better than supine? Int J Radiat Oncol Biol Phys,2000,47: 365-371.
  • 3McLaughlin PW, Wygoda A, Sahijdak W, et al. The effect of patient position and treatment technique in conformal treatment of prostate cancer. Int J Radiat Oncol Biol Phys,1999,45:407-413.
  • 4Koelbl O, Richter S, Flentje M. Influence of patient positioning on dose-volume histogram and normal tissue complication probability for small bowel and bladder in patients receiving pelvic irradiation: a prospective study using a 3D planning system and a radiobiological model. Int J Radiat Oncol Biol Phys, 1999,45:1193-1198.
  • 5Adli M, Mayr NA, Kaiser HS, et al. Does prone positioning reduce small bowel dose in pelvic radiation with intensity-modulated radiotherapy for gynecologic cancer? Int J Radiat Oncol Biol Phys,2003,57:230-238.
  • 6Wachter S, Gerstner N, Dorner D, et al. The influence of a rectal balloon tube as internal immobilization device on variations of volumes and dose-volume histograms during treatment course of conformal radiotherapy for prostate cancer. Int J Radiat Oncol Biol Phys,2002,52:91-100.
  • 7Gerstner N, Wachter S, Dorner D, et al. Significance of a rectal balloon as internal immobilization device in conformal radiotherapy of prostatic carcinoma. Strahlenther Onkol, 1999,175:232-238.
  • 8Italia C, Fiorino C, Ciocca M, et al. Quality control by portal film analysis in radiotherapy for prostate cancer: a comparison between two different institutions and treatment teehniques. Tumori, 1998,84:640-648.
  • 9Bayley A J, Catton CN, Haycocks T, et al. A randomized trial of supine vs. prone positioning in patients undergoing escalated dose conformal radiotherapy for prostate cancer. Radiother Oncol,2004,70:37-44.
  • 10Kitaruura K, Shirato H, Seppenwoolde Y, et al. Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions. Int J Radiat Oncol Biol Phys,2002,53:1117-1123.

共引文献25

同被引文献10

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部