期刊文献+

基于非均匀有理B样条的四维心脏-躯干体模及其在医学影像研究中的应用 被引量:1

The four-dimensional non-uniform rational B-splines-based cardiac-torso phantom and its application in medical imaging research
原文传递
导出
摘要 在医学影像研究中,新的医学影像研究工具模拟方式的作用日益重要。基于非均匀有理B样条的四维心脏.躯干(4DNCAT)体模是在成像处理时,采用影像处理精确模型就能够提供来自受试者不同解剖部位的成像数据。4DNCAT已广泛用于SPECT、PET、CT等医学影像研究,并已用于调强放射治疗四维逆向计划系统。 Simulation skill is playing an increasingly important role in medical imaging research. four-dimensional non-uniform rational B-splines-based cardiac-torso (4D NCAT) phantom is new tool for meoical imaging res earch and when combined with accurate models for the imaging process a wealth of realistic imaging data from subjects of various anatomies. Can be provided 4D NCAT phantoms have bend widely used in medical research such as SPECT, PET, CT and so on. 4D NCAT phantoms have also been used in inverse planning system of intensity modulated radiation therapy.
出处 《国际放射医学核医学杂志》 2008年第6期367-371,共5页 International Journal of Radiation Medicine and Nuclear Medicine
基金 四川省科技厅应用基础项目(07JY029-061)
关键词 体层摄影术 发射型计算机 单光子 体层摄影术 X线计算机 体模 显像术 计算机模拟 Tomography, emission-computed, single-photon Tomography, X-ray computed Phantoms, imaging Computer simulation
  • 相关文献

参考文献20

  • 1张居营,徐榭,石成玉.四维动态数字人体模型的开发及其在放疗计划中评估器官呼吸运动影响的研究[J].中国医学影像技术,2006,22(9):1301-1305. 被引量:4
  • 2Segars WP, Tsui BMW. Study of the efficacy of respiratory gating in myocardial SPECT using the new 4D NCAT phantom [J/OL]. Nuclear Science Symposium Conference Record, IEEE Xplore, 2001, 3: 1536-1539. http://ieeexplore, ieee. org/Xplore/login, jsp? url--http%3A%2F%2Fieeexplore, ieee. org%2Fie15%2F7884% 2F21744% 2F01008630. pdf% 3Farnumber% 3D1008630 & auth Decision=-203.
  • 3徐谢,赵自强,石成玉,张田田.基于美国可视人项目图像的成年男子解剖模型及其在医学虚拟仿真上的应用[J].中国基础科学,2002(6):25-30. 被引量:9
  • 4Lomsky M, Richter J, Johansson L, et al. A new automated method for analysis of gated-SPECT images based on a three-dimensional heart shaped model [J]. Clin Physiol Funct Imaging, 2005, 25(4): 234-240.
  • 5Luyt N, Wells RG. Imaging of hepatic hemangiomas using multi- rotation dynamic SPECT[J/OL]. Nuclear Science Symposium Conference Record, IEEE Xplore, 2003, 4:2932-2936. http:// ieeexplore, ieee.org/Xplore/login.jsp?url=http%3A% 2F%2Fieeexplore, ieee.org% 2Fie15% 2F9356% 2F29716% 2F01352498. pdf&authDecision=-203.
  • 6Lorena S Correa Prado, E Andres Valdez Diaz, Rafil Romo. Elastic models application for thorax image registration[J/OL]. J Phys: Conf Ser, 2007, 1-9. http://www.iop.org/EJ/abstract/1742-6596/90/1/ 012055.
  • 7Smyczynski MS, Segars WP, Narayanan MV, et al. Modeling the respiratory motion of solitary pulmonary nodules for investigating SPECT tumor imaging[J/OL]. Nuclear Science Symposium Conference Record, IEEE Xplore, 2001, 3: 1371-1375. http:// ieeexplore.ieee.org/Xplore/login.j sp?url =http% 3A% 2F% 2 Fieeexplore.ieee.org% 2Fiel5 % 2F7884% 2F21744% 2F01008592.pdf& authDecision=-203.
  • 8Lee TS, Segars WP, Tsui BMW. A study of the effect of cardiac gating in myocardial SPECT using the 4D NCAT[J/OL]. Nuclear Science Symposium Conference Record IEEE Xplore, 2003, 4: 2681-2685. http://ieeexplore.ieee.org/Xplore/login, jsp?url=http% 3A% 2F% 2Fieeexplore.ieee.org% 2Fie15% 2F9356% 2F29716% 2F01352440.pdf&authDecision=-203.
  • 9Sayeram S, Lalush DS. Performance evaluation of 4D reconstruction methods for gated cardiac single photon emission computed tomography in obese patients [J/OL]. Comput Cardiol , 2007, 34: 3717374. http://ieeexplore.ieee.org/xpl/freeabs_all.jsp? isnumber=4745405&arnumber=4745499&eount=217&index=93.
  • 10Faber TL, Modersitzki J, Folks RD, et al. Detecting changes in serial myocardial perfusion SPECT: a simulation study [J]. J Nucl Cardiol, 2005, 12(3): 302-310.

二级参考文献67

  • 1赵国英,陈睿,张俊,林宗楷,李华.数字人与人体仿真[J].计算机仿真,2003,20(z1):520-524. 被引量:7
  • 2张晓斌,魏永祥,韩德民.数字化虚拟人体与鼻外科[J].国外医学(耳鼻咽喉科学分册),2005,29(1):44-48. 被引量:7
  • 3刘芳,陈英茂,白净.基于医学图像处理的放射性药物内照射剂量计算[J].北京生物医学工程,2007,26(2):120-123. 被引量:2
  • 4Xu XG,Chao TC,Bozkurt A.VIP-Man:an image-based whole-body adult male model constructed from color photographs of the visible human project for multi-particle Monte Carlo calculations[J].Health Phys,2000,78(5):476-486.
  • 5National Library of Medicine (US) Board of Regents.Electronic imaging:report of the board of regents.US:Department of Health and Human Services,Public Health Service,National Institutes of Health,1990:90-2197.
  • 6Ackerman MJ.Accessing the visible human project.D-lib Magazine:The Magazine of the Digital Library Forum[DB/OL].http://www.dlib.org/dlib/october95/10ackerman.html,1995-10.
  • 7Bozkurt A,Chao TC,Xu XG.Fluence-to-dose conversion coefficients from monoenergetic neutron beams below 20 MeV based on the VIP-Man anatomical model[J].Phys Med Biol,2000,45(10):3059-3079.
  • 8Chao TC,Xu XG.Specific absorbed fractions from the image-based VIP-Man body model and EGS4-VLSI Monte Carlo code:internal electron emitters[J].Phys Med Biol,2001,46(4):901-927.
  • 9Chao TC,Bozkurt A,Xu XG.Conversion coefficients based on VIP-Man anatomical model and EGS4-VLSI code for monoenergetic photon beams from 10 keV to 10 MeV[J].Health Phys,2001,81(2):163-183.
  • 10Bozkurt A,Chao TC,Xu XG.Fluence-to-dose conversion coefficients based on the VIP-Man anatomical model and MCNPX Code for monoenergetic neutron beams above 20 MeV[J].Health Phys,2001,81(2):184-202.