夏热冬冷地区公共建筑热工性能评估方法的讨论 被引量:5

Discussion of evaluation method of thermal performance of public buildings in hot summer and cold winter zone
下载PDF
导出
摘要 针对《公共建筑节能设计标准》中热工性能评估的个别条款在夏热冬冷地区执行时的疑问,进行了探讨。标准未限定围护结构热工性能强制指标的适用范围,笔者认为不应包括非供暖空调建筑和建筑中的非供暖空调区域;标准规定权衡判断以全年供暖空调能耗为依据,笔者建议供暖空调的设计负荷或全年的累计负荷也可作为权衡判断依据,以简化权衡判断的计算过程。 Discusses some doubts raised in implementing the Design standard for energy efficiency of public buildings as be applied in hot summer and cold winter zone. Application scope of mandatory indexes about thermal performance of building envelopes in the standard is not be limited to heated and air conditioned building and heated and air conditioned area in a building. Trade off option is complex when annual heating and air conditioning energy consumption is the index. Proposes design load or annual accumulated load in place of annual energy consumption to simplify the trade off.
作者 雷飞 胡平放
机构地区 华中科技大学
出处 《暖通空调》 北大核心 2009年第3期70-72,共3页 Heating Ventilating & Air Conditioning
关键词 设计标准 夏热冬冷地区 围护结构 热工性能 权衡判断 design standard, hot summer and cold winter zone, envelope, thermal performance, trade off option
  • 相关文献

参考文献5

二级参考文献5

  • 1[1]GB50189-2005,公共建筑节能设计标准[S].(GB50189-2005,Design standard for energy efficiency of public buildings[S].)
  • 2GB50189-2005.公共建筑节能设计标准[S].[S].,2005..
  • 3GB 18613-2002中小型三拍异步电动机能效限高阶段接评价值[S].
  • 4GB/T 19232-2003风机盘管机组[S].
  • 5付祥钊.夏热冬冷地区建筑热环境与能耗状况[J].建筑技术,1998,29(10):691-692. 被引量:9