期刊文献+

外墙外保温系统的裂缝控制 被引量:4

CRACK CONTROL OF EXTERIOR THERMAL INSULATION SYSTEM OF EXTERNAL WALL
下载PDF
导出
摘要 叙述外墙外保温系统的多层复合技术,说明其构造的合理性、适用性和裂缝产生的可能性。提出在"抗放结合,以放为主"原则下,以材料性质逐层渐变、变形应力逐层释放的手段,采取减小层间约束,增强材料延性,邻层材料变形求相近、匹配相容求相宜,分隔设缝、防水透气等措施,以达到控制裂缝的目的。 Multilayer composite technology of exterior thermal insulation system of external wall is introduced herein, and rationality and applicability of this technology and possibility for generation of cracks are explained. On principle of prevention and release, measures are adopted to reduce constraint between layers,improve ductility of material, realize similar material deformation between adjacent layers, adopt different matching consistency, set isolation joints and improve waterproof property and air permeability, so as to control cracks.
作者 邱玉深 邱静
出处 《建筑技术》 北大核心 2009年第4期354-356,共3页 Architecture Technology
关键词 建筑节能 外墙保温 复合墙体 building energy saving external wall thermal insulation composite wall
  • 相关文献

参考文献7

二级参考文献2

  • 1JG149-2003.膨胀聚苯板薄抹灰外墙外保温系统[S].[S].,..
  • 2JGJ144-2004.外墙外保温工程技术规程[S].[S].,..

共引文献39

同被引文献15

引证文献4

二级引证文献8