摘要 白内障术前人工晶状体(intraocular lens,IOL)度数测量的精确性直接影响术后屈光结果。IOL-Master是一种较新的非接触性测量IOL度数的手段。本文就IOL-Master测量IOL的原理、应用、优缺点以及最新进展作一综述。 Pre-operative accurate prediction of the intraocular lens (IOL) power directly influences refractive outcome after cataract surgery. IOL-Master is a new non-contact IOL power measurement. This article reviews the principle, application, advantage or disadvantage and prospect of IOL-Master.
出处 《眼科新进展》 CAS 北大核心 2009年第4期315-319,共5页 Recent Advances in Ophthalmology
关键词 IOL—Master 前房深度 眼轴 人工晶状体度数 IOL-Master anterior chamber depth axis oculi intraocular lens power
  • 相关文献

参考文献36

  • 1Olsen T. Sources of error in intraocular lens power calculation [J]. J Cataract Refract Surg 1992 ; 18 ( 2 ) : 125-129.
  • 2Connors R 3rd, Boseman P 3rd, Olson RJ. Accmacy and reproducibility of biometry using partial coherence interferometry [J]. J Cataract Refract Surg 2002;28(2) :235-238.
  • 3Drexler W, Findl O, Menapace R, Rainer G, Vass C, Hitzenberger CK, et al. Partial coherence interferometry:a novel approach to biometry in cataract surgery[J]. Am J Ophthalmol 1998 ; 126 (4) :524-534.
  • 4Holladay JT, Prager TC, Ruiz RS, Lewis JW, Rosenthal H. Improving the predictability of intraocular lens power calculations [ J ]. Arch Ophthalmol 1986 ; 104 (4) :539-541.
  • 5张亚丽,赵云娥,王勤美.用A超、B超及IOL-Master测量高度近视白内障眼轴的精确性比较[J].中国实用眼科杂志,2005,23(9):972-974. 被引量:19
  • 6刘平,石广森.IOL-MASTER测量人工晶体屈光度的精确性研究[J].中国实用眼科杂志,2006,24(8):786-788. 被引量:18
  • 7宁远,赵江月,张劲松.IOL-Master对高度近视眼人工晶状体度数测量的临床研究[J].眼科新进展,2008,28(5):373-375. 被引量:10
  • 8MacLaren RE, Natkunarajah M, Riaz Y, Bourne RR, Restori M, Allan BD. Biometry and formula accuracy with intraocular lenses used for cataract surgery in extreme hyperopia[J]. Am J Ophthalmol 2007 ; 143 ( 6 ) :920-931.
  • 9徐慧艳,李一壮,卢善华.人工晶状体屈光度IOL Master测算的精确度[J].眼外伤职业眼病杂志,2007,29(11):852-855. 被引量:6
  • 10Prhlz A, Neumayer T, Buehl W, Kiss B, Sacu S, Drexler W, et al. Influence of severity of nuclear cataract on optical biometry[J]. J Cataract Refract Surg 2006;32(7) :1161-1165.

二级参考文献43

  • 1张亚丽,赵云娥,王勤美.光学相干生物测量仪测量人工晶状体度数精确性的评价[J].眼视光学杂志,2005,7(1):41-43. 被引量:11
  • 2Findl O, Drexler W, Menapace R, et al. Improved predication of intraocular lens power using partial coherence interferometry. J Cataract Refract Surg, 2001,27: 861
  • 3王丽娅,裴国宾.超声乳化术前检查与准备.见:郭海科主编.白内障超声乳化与人工晶状体植入术.郑州:河南医科大学出版社,2000,59-60
  • 4Haigis W, Lege B, Miller N, et al. Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Grafe's Arch Clin Exp Ophthalmol,2000,238: 765
  • 5Packer M, Fine H, Hoffman RS, et al. Immersion Ascan compared with partial coherence interferometry outcomes analysis. J Cataract Refract Surg, 2002, 28:239
  • 6Connors R, Boseman P, Olson RJ. Accuracy and reproducibility of biometry using partial coherence interferometry. J Cataract Refract Surg,2002, 28: 235
  • 7Collette S. L. Tsang, Gabriela S. L. Chong, Evan P. F.Yiu, et al. Intraocular lens power calculation formulas in Chinese eyes with high axial maopia. J Cataract Refract Surg, 2003, 29(7): 1358- 1364
  • 8H. John Shammas. Intraocular Lens Power Calculation. America: SLACK Incoporated, 2004, 161
  • 9R. Bruce Wallace Ⅲ. Refractive cataract surgery and multifocal iols. Canada: SLACK Incoporated, 2001, 21-31
  • 10Binkhorst RD. The accuracy of ultrasonic measurement of the axial eye length. Ophthalmic Surg, 1981, 12 (5): 363- 365