期刊文献+

Enantiomeric separation of phenylsuccinic acid by cyclodextrin-modified reversed phase high-performance liquid chromatography 被引量:1

Enantiomeric separation of phenylsuccinic acid by cyclodextrin-modified reversed phase high-performance liquid chromatography
下载PDF
导出
摘要 The chiral separation of phenylsuccinic acid(PSA)was studied by reversed phase high-performance liquid chromatography(RP-HPLC)with cyclodextrins(CDs)as chiral mobile phase additives.The effects of types of CDs,concentration of hydroxypropyl-β-cyclodextrin(HP-β-CD),percentage of organic modifier,pH value and column temperature on enantioselective separation were investigated.The quantification property of the developed RP-HPLC method was examined.The chiral recognition mechanism of PSA was also discussed.The results show that a baseline separation of PSA enantiomers is achieved on a Lichrospher C18 column(4.6 mm(inner diameter)×250 mm,5μm)with HP-β-CD as chiral mobile phase additive.The capacity factors of R-PSA and S-PSA are 3.94 and 4.80,respectively.The separation factor and resolution are respectively 1.22 and 8.03.The mobile phase is a mixture of acetonitrile and deionized water(20-80,volume ratio)containing 10 mmol/L HP-β-CD and 0.05% trifluoroacetic acid(pH 2.5,adjusted with triethylamine)with a flow rate of 1.0 mL/min.The ultraviolet(UV)detector is set at 254 nm.The likely roles are inclusion interaction,induction and hydrogen bonding between HP-β-CD and PSA enantiomers. The chiral separation of phenylsuccinic acid (PSA) was studied by reversed phase high-performance liquid chromatography (RP-HPLC) with cyclodextrins (CDs) as chiral mobile phase additives. The effects of types of CDs, concentration of hydroxypropyl-β-cyclodextrin (HP-β-CD), percentage of organic modifier, pH value and column temperature on enantioselective separation were investigated. The quantification property of the developed RP-HPLC method was examined. The chiral recognition mechanism of PSA was also discussed. The results show that a baseline separation of PSA enantiomers is achieved on a Lichrospher C18 column (4.6 mm (inner diameter)×250 mm, 5 μm) with HP-β-CD as chiral mobile phase additive. The capacity factors of R-PSA and S-PSA are 3.94 and 4.80, respectively. The separation factor and resolution are respectively 1.22 and 8.03. The mobile phase is a mixture of acetonitrile and deionized water (20:80, volume ratio) containing 10 mmol/L HP-β-CD and 0.05% trifluoroacetic acid (pH 2.5, adjusted with triethylamine) with a flow rate of 1.0 mL/min, The ultraviolet (UV) detector is set at 254 nm. The likely roles are inclusion interaction, induction and hydrogen bonding between HP-β-CD and PSA enantiomers.
出处 《Journal of Central South University》 SCIE EI CAS 2009年第2期201-205,共5页 中南大学学报(英文版)
基金 Project(20776038)supported by the National Natural Science Foundation of China
关键词 反相高效液相色谱法 有机改性剂 环糊精 手性拆分 手性流动相添加剂 CD光盘 HPLC法 手性分离 high performance liquid chromatography hydroxypropyl-β-cyclodextrin enantiomer separation phenylsuccinic acid
  • 相关文献

参考文献2

二级参考文献6

共引文献13

同被引文献5

引证文献1

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部